'15 • SRK-T-172
Model
Item
SRK10CRS-S3
Indoor unit
SRK10CRS-S3
Outdoor unit
SRC10CRS-S3
Cooling capacity (1)
W
2700
Power source
1 Phase, 220-240V, 50Hz
Operation
data
Power
consumption
Cooling
kW
0.740
Running
current
Cooling
A
3.4
Inrush current
8.9
COP
Cooling
3.65
Noise
level
Cooling
Sound level
dB(A)
Hi : 40 Me : 37 Lo : 35
48
Power level
dB
54
59
Exterior dimensions (Height x Width x Depth)
mm
268 x 790 x 222
540 x 780(+62) x 290
Exterior appearance
(Munsell color)
Fine snow
(8.0Y 9.3/0.1) near equivalent
Stucco white
(4.2Y 7.5/1.1) near equivalent
Net weight
kg
9.5
28.5
Refrigerant
equipment
Compressor type & Q'ty
—
ASM99V1VDZ ( Rotary type ) x 1
Motor (Starting method)
kW
—
PSC
Refrigerant oil
0.35 ( ESTEL OIL VG74 )
Refrigerant (4)
kg
R410A 0.58 ( Pre-charged up to the piping length of 5 m )
Heat exchanger
Louver fins & inner grooved tubing
Louver fins & inner grooved tubing
Refrigerant control
Capillary tubes
Device control
Microcomputer control
Air handling
equipment
Fan type & Q'ty
Tangential fan x 1
Propeller fan x 1
Motor
W
16
15
Air flow
Cooling
m
3
/min
10
26.5
Fresh air intake
Not possible
—
Air filter, Quality / Quantity
Polypropylene net (washable) x 2
—
Shock & vibration absorber
—
Cushion rubber (for compressor)
Operation
control
Operation switch
Wireless remote control
—
Room temperature control
Microcomputer thermostat
—
Operation display
RUN : Green , TIMER : Yellow , HI POWER : Green ,
3D AUTO : Green
Safety devices
Compressor overheat protection,
Frost protection, Serial signal error protection,Fan motor error protection,
Installation
data
Refrigerant piping size (O.D)
mm
Liquid line:
φ
6.35 (1/4") Gas line:
φ
9.52 (5/8")
Connecting method
Flare connecting
Attached length of piping
m
Liquid line : 0.57
Gas line : 0.55
—
Insulation for piping
Necessary (Both sides), independent
Refrigerant line (one way) length
m
Max. 15
Vertical height difference between
outdoor unit and indoor unit
Max.5 (Outdoor unit is higher)
Max.5 (Outdoor unit is lower)
Drain hose
Connectable (VP 16)
—
Power cable
2m (3 Cores wih Earth)
Recommended breaker size
A
20
Connection wiring
Size x Core number
1.5mm
2
x 3 cores (Including earth cable)
Connecting method
Terminal block (Screw fixing type)
Accessories (included)
Mounting kit
Option parts
—
Note (1) The data are measured at the following conditions.
Item
Operation
Indoor air temperature
Outdoor air temperature
Standards
DB
WB
DB
WB
Cooling
27˚C
19˚C
35˚C
24˚C
ISO-T1 , JIS C 9612
(2) This air-conditioner is manufactured and tested in conformity with the ISO.
(3) The operation data are applied to the 230 V districts respectively.
(4) The refrigerant quantity to be charged includes the refrigerant in 5m connecting piping.
(Purging is not required even for the short piping.)
If the piping length is 5m to 15m, additional refrigerant is 10g per each 1m longer than 5 m.
The pipe length is 5m.
All manuals and user guides at all-guides.com
Summary of Contents for SRK10CRS-S
Page 2: ...All manuals and user guides at all guides com ...
Page 3: ... 15 SRK T 172 TECHNICAL MANUAL All manuals and user guides at all guides com ...
Page 60: ... 58 All manuals and user guides at all guides com ...
Page 64: ... 62 15 SRK T 172 4 6 10641 All manuals and user guides at all guides com ...
Page 68: ... 66 15 SRK T 172 4 6 10641 All manuals and user guides at all guides com ...
Page 72: ... 70 15 SRK T 172 4 6 10641 All manuals and user guides at all guides com ...