'15 • SRK-T-172
(2)
Unit ON/OFF button
When the remote control batteries become weak, or if the remote control is lost or malfunctioning, this button may be used to
turn the unit on and off.
(a) Operation
Push the button once to place the unit in the automatic mode. Push it once more to turn the unit off.
(b) Details of operation
The unit will go into the automatic mode in which it automatically determines, from room temperature (as detected by
sensor), whether to go into COOL or DRY modes.
(3)
Auto restart function
(a)
Auto restart function records the operational status of the air-conditioner immediately prior to be switched off by a power
cut, and then automatically resumes operations after the power has been restored.
(b)
The following settings will be cancelled:
(i)
Timer settings
(ii)
HIGH POWER operations
Notes () Auto restart function is set at on when the air-conditioner is shipped from the factory.
Consult with your dealer if this function needs to be switched off.
() When power failure ocurrs, the timer setting is cancelled. Once power is resumed, reset
the timer.
() If the jumper wire (J) “AUTO RESTART” is cut, auto restart is disabled. (See the diagram
at right)
(4)
Custom cord switching procedure
If two wireless remote control are installed in one room, in order to prevent wrong
operation due to mixed signals, please modify the printed circuit board in the indoor
unit’s control box and the remote control using the following procedure. Be sure to
modify both boards. If only one board is modified, receiving (and operation) can
-
not be done.
(a) Modifying the indoor unit’s printed circuit board
Take out the printed circuit board from the control box and cut off jumper
wire (J) using wire cutters.
After cutting of the jumper wire, take measures to prevent contact with the other
the lead wires, etc.
(b) Modifying the wireless remote control
(i) Remove the battery.
(ii) Cut the jumper wire shown in the figure at right.
Cut
Function
Operation mode
Room temperature
setting
Fan speed
Flap
Timer switch
COOL
About ºC
Auto
Auto
Continuous
DRY
About ºC
Jumper wire (J6)
Jumper wire (J7)
Jumper wire (J6)
Jumper wire (J7)
– 6 –
Unit indication section
SRK10YJV-S
SRK13YJV-S
How to open the air inlet panel
Push both sides evenly and press further lightly at the center.
Place fingers at the recesses on both sides of the panel and pull up the panel
to this side so that it will be opened by about 60 degrees.
Unit ON/OFF button
Secure either the upper or lower edge of the air inlet panel by lightly pushing it
in, and then close the panel.
When removing the air inlet panel for internal cleaning or others, open the
panel by 80 degrees and then pull it to this side.
In emergencies, this button can be used for turning on/off the unit when
remote control is not available.
Page 15
Removal, installation of air inlet panel
3D AUTO light (green)
Illuminates during 3D AUTO operation.
HI POWER light (green)
Illuminates during HIGH POWER operation.
RUN light (green)
Illuminates during operation
and CLEAN operation.
TIMER light (yellow)
Illuminates during TIMER operation.
Unit ON/OFF button
How to close the air inlet panel
RMA012A032_En.p65
04/05/2010, 17:26
6
Unit ON/OFF button
All manuals and user guides at all-guides.com
Summary of Contents for SRK10CRS-S
Page 2: ...All manuals and user guides at all guides com ...
Page 3: ... 15 SRK T 172 TECHNICAL MANUAL All manuals and user guides at all guides com ...
Page 60: ... 58 All manuals and user guides at all guides com ...
Page 64: ... 62 15 SRK T 172 4 6 10641 All manuals and user guides at all guides com ...
Page 68: ... 66 15 SRK T 172 4 6 10641 All manuals and user guides at all guides com ...
Page 72: ... 70 15 SRK T 172 4 6 10641 All manuals and user guides at all guides com ...