103
-
12
Function No. A
(Example) If the upper limit is set at 28˚C
Function Contents B
Setting Contents C
TEMP RANGE SET
DISP CHANGE
NO DISP CHANGE
Control Contents
The remote control’s display and sent
data upper limit changes to 28
°
C.
The remote control’s display upper limit
remains at 30ºC and only the upper limit
of the sent data is changed to 28
°
C.
(iv) Changing the remote control’s temperature setting range
1) The temperature setting range of the remote control can be changed.
Through remote control button operations, the upper limit and lower limit set temperature values can be changed indi-
vidually.
During heating operation, the changed upper limit value becomes valid and at times other than during heating operation,
(during cooling, dehumidification, auto and fan operation), the changed lower limit value becomes valid.
Range of Possible Changes
Upper Limit Value: 22~30ºC (valid during heating) Lower Limit Value: 18 ~ 26ºC (valid at times other than during
heating)
2) Operation
a) With the remote control in the stopped state, press the SET and MODE buttons simultaneously for 3 seconds or
longer. The display will changed from “
SELECT ITEM”
“
SET”
“FUNCTION SET
”
b) Press the
button once. The display will change to TEMP RANGE
.
c) Press the SET button to enter the temperature range setting mode.
d) Using the
or
button, select “Hi LIMIT SET
” or “Lo LIMIT SET ,” the press the SET button.
e) If “Hi LIMIT SET” is selected,
1
The display changes from “
SET UP”
“Hi LIMIT 22ºC
” (flashing).
2
Using the “
” button, select the upper limit value. Display example: “Hi LIMIT 22ºC
” (flashing)
3
Press the SET button to fix the setting. Display example: “Hi LIMIT 22ºC” (lighted up)
f) If “Lo LIMIT SET” is selected,
1
The display changes from “
SET UP”
“Lo LIMIT 26ºC
” (flashing).
2
Using the “
” button, select the upper limit value. Display example: “Lo LIMIT 26ºC
” (flashing)
3
Press the SET button to fix the setting. Display example: “Lo LIMIT 26ºC” (lighted up)
g) Press the ON/OFF button to end the setting procedure.
(The procedure also ends if the ON/OFF button is pressed during the setting operation. However, settings which have
not been fixed become invalid, so exercise caution.)
• If the RESET button is pressed during a setting operation, the display returns to the previously displayed setting screen.
However, settings which have not been fixed become invalid, so exercise caution.
* If “NO DISP CHANGE” is selected in No. 12, “TEMP RANGE SET” of the remote control’s functions, of the function
setting modes, the remote control’s display does not change even if the temperature range has been changed.
Summary of Contents for SRK13ZEV-S4
Page 2: ...TECHNICAL MANUAL 1 SRK13ZEV S4 2 2 SRK22ZEV S4 60 1 ...
Page 126: ...PARTS LIST INDOOR UNIT SRK13ZEV S4 SRK22ZEV S4 OUTDOOR UNIT SRC13ZEV S4 SRC22ZEV S4 125 ...
Page 134: ...MEMO 133 ...
Page 137: ... 136 CRBE0226 1 3 4 2 5 6 7 8 9 10 11 12 13 PANEL FAN ASSY ...
Page 145: ...ROOM AIR CONDITIONING TECHNICAL MANUAL PARTS LIST Manual No 06 SRK T 054 ...