62
-
Item
Model
SRK22ZEV-S4
SRC22ZEV-S4
Cooling capacity
(1)
W
6300 (900~7100)
Heating capacity
(1)
W
7100 (900~9000)
Power source
1 Phase, 220V, 50Hz
Cooling input
kW
1.84
Running current (Cooling)
A
8.4
Heating input
kW
1.86
Running current (Heating)
A
8.5
Inrush current
A
8.5
COP
Cooling: 3.42 Heating: 3.82
Cooling
Sound level
Hi 43, Me 39, Lo 33, ULo 26
47
Noise level
Power level
dB
58
62
Heating
Sound level
Hi 44, Me 38, Lo 32, ULo 27
48
Power level
59
63
Exterior dimensions
Height
×
Width
×
Depth
mm
318
×
1098
×
248
750
×
880
×
340
Color
Yellowish white
Stucco white
Net weight
kg
15
59
Refrigerant equipment
Compressor type & Q’ty
–
TNB220FLBM1 (Twin rotary type)
×
1
Motor
kW
–
1.3
Starting method
–
Line starting
Heat exchanger
Slit fins & inner grooved tubing
Straight fin & inner grooved tubing
Refrigerant control
Capillary tubes + Electronic expansion valve
Refrigerant
(3)
kg
R410A 1.9 (Pre-Charged up to the piping length of 15m)
Refrigerant oil
R
0.67 (MEL56)
Deice control
Microcomputer control
Air handling equipment
Fan type & Q’ty
Tangential fan
×
1
Propeller fan
×
1
Motor
W
46
86
(Cooling)
18.5
46
Air flow (at High)
(Heating)
CMM
21
46
Air filter, Q’ty
Polypropylene net (washable)
×
2
–
Shock & vibration absorber
–
Cushion rubber (for compressor)
Electric heater
–
–
Operation control
Operation switch
Wireless-Remote control
–
Room temperature control
Microcomputer thermostat
–
Pilot lamp
RUN (Green), TIMER (Yellow), HI POWER (Green), ECONO (Orange)
Safety equipment
O.D
mm (in)
Liquid line:
φ
6.35 (1/4
″
)
Gas line:
φ
15.88 (5/8
″
)
Connecting method
Flare connecting
Attached length of piping
Liquid line: 0.70m
Gas line : 0.63m
–
Insulation
Necessary (Both sides)
Drain hose
Connectable
Power source supply
Terminal block (Screw fixing type)
Size
×
Core number
1.5 mm
2
×
4 cores (Including earth cable)
Connection wiring
Connecting method
Terminal block (Screw fixing type)
Accessories (included)
Mounting kit, Clean filter (Allergen clear filter
×
1, Photocatalytic washable deodorizing filter
×
1)
Optional parts
Wired-Remote control
Notes (1) The data are measured at the following conditions.
2.2 SELECTION DATA
(1)
Specifications
Model SRK22ZEV-S4 (Indoor unit)
SRC22ZEV-S4 (Outdoor unit)
Item
Indoor air temperature
Outdoor air temperature
Standards
Operation
DB
WB
DB
WB
Cooling
27ºC
19ºC
35ºC
24ºC
ISO-T1, JIS C9612
Heating
20ºC
–
7ºC
6ºC
ISO-T1, JIS C9612
(2) The operation data are applied to 220V destricts respecitively.
(3) The refrigerant quantity to be charged includes the refrigerant in 15 m connecting piping.
(Purging is not required even for the short piping.)
If the piping length is longer, when it is 15 to 30 m, add 25g refrigerant per meter.
Operation data
(1)
Refrig
erant
piping
Compressor overheat protection, Heating overload protection (High pressure control), Overcurrent protection,
Frost protection, Serial signal error protection, Indoor fan motor error protection, Cooling overload protection
The piping length is 7.5m.
(220V)
Summary of Contents for SRK13ZEV-S4
Page 2: ...TECHNICAL MANUAL 1 SRK13ZEV S4 2 2 SRK22ZEV S4 60 1 ...
Page 126: ...PARTS LIST INDOOR UNIT SRK13ZEV S4 SRK22ZEV S4 OUTDOOR UNIT SRC13ZEV S4 SRC22ZEV S4 125 ...
Page 134: ...MEMO 133 ...
Page 137: ... 136 CRBE0226 1 3 4 2 5 6 7 8 9 10 11 12 13 PANEL FAN ASSY ...
Page 145: ...ROOM AIR CONDITIONING TECHNICAL MANUAL PARTS LIST Manual No 06 SRK T 054 ...