'16 • SRK-T-192
Preparation of indoor unit
Pipe
Drain hose
1. Remove the drain hose.
2. Remove the drain cap.
3. Insert the drain cap.
4. Connect the drain hose.
①
Mounting of connecting wires
ⓐ
Remove the lid.
ⓑ
Remove the wiring clamp.
ⓒ
Connect the connecting wire securely to the terminal block.
Use cable for interconnection wiring to avoid loosening of the
wires.
CENELEC code for cables Required field cables.
H05RNR4G1.5 (Example) or 245IEC57
H
Harmonized cable type
05 300/500 volts
R
Natural-and/or synth. rubber wire insulation
N
Polychloroprene rubber conductors insulation
R
Standed core
4or5 Number of conductors
G
One conductor of the cables is the earth conductor
(yellow/green)
1.5 Section of copper wire (mm
2
)
•
Connect the connection wire securely to the terminal block.
If the wire is not affixed completely, contact will be poor,
and it is dangerous as the terminal block may heat up and
catch fire.
•
Take care not to confuse the terminal numbers for indoor
and outdoor connections.
•
Earth lead wire shall be longer than the other lead wires for
the electrical safety in case of the slipping out of the cord
from the anchorage.
•
The earth line of power cable must be properly earthed.
•
Affix the connection wire using the wiring clamp.
ⓓ
Fix the connecting wire by wiring clamp.
ⓔ
Attach the lid.
ⓕ
Close the air inlet panel.
②
Shaping the pipe
③
Taping of the exterior
Hold the bottom of the pipe and change its direction before
stretching it and shaping it.
•
Tape only the portion that runs through the wall.
Always tape the crossover wires with the pipe.
•
•
④
Cautions when piping from the left and the rear center of the unit
[ Top View ]
Remove the screw and
drain hose, making it
rotate.
•
Remove it with hand
or pliers.
•
Insert the drain cap which was
removed at procedure “2” securely
using a hexagonal wrench etc.
Note: Be careful that If it is not
Inserted securely, water leakage may
occur.
•
Insert the drain hose securely,
making rotate. And install the
screw.
Note: Be careful that if it is
not inserted securely, water
leakage may occur.
•
Left side piping
Right side piping
Right rear piping
Left rear piping
Left side piping
Right side piping
[Drain hose changing procedures]
Left downward
Right
Rear
Downward Left rear
Left
Piping is possible in the rear, left,
left rear, left downward, right or
downward direction.
•
Do not place the power cable above the gutter, because
the air-conditioner is structured in a way where condensa-
tion on the back side is collected in to the drain pan before
drainage.
Do not make traps in the drain hose line.
•
* Leave space to allow
removal of this screw
after installation.
Wall
Gutter
Pipes storage area
Declining slope
Inverted slipe
Trap
Terminal block
Clamp
Lid (R)
Screw*
Summary of Contents for SRK18YLV-S1
Page 2: ......
Page 3: ...TECHNICAL MANUAL ...
Page 9: ... 16 SRK T 192 3 Wireless remote control Unit mm 60 17 3 150 ...
Page 53: ... 50 16 SRK T 192 ...
Page 54: ... 51 16 SRK T 192 PARTS LIST INDOOR UNIT SRK18YLV S1 OUTDOOR UNIT SRC18YLV S1 ...
Page 59: ... 56 16 SRK T 192 CRBE0294 6 13 11 18 12 15 16 3 17 14 2 4 9 8 7 5 1 8 8 10 PANEL FAN ASSY ...