-
3
-
Model SRK28HG (Indoor unit)
SRC28HG (Outdoor unit)
Item
Model
SRK28HG
SRC28HG
Cooling capacity
(1)
W
2530
Heating capacity
(1)
W
2670
Power source
1 Phase, 220/230/240V, 50Hz
Cooling input
kW
0.77
Running current (Cooling)
A
3.6/3.4/3.2
Heating input
kW
0.685
Running current (Heating)
A
3.2/3.0/2.8
Inrush current
A
16.4
COP
Cooling: 3.29 Heating: 3.90
Cooling
Sound level
Hi: 39, Me: 33, Lo: 30
45
Noise level
Power level
dB
55
60
Heating
Sound level
Hi: 39, Me: 33, Lo: 29
44
Power level
56
60
Exterior dimensions
Height
×
Width
×
Depth
mm
268
×
790
×
199
540
×
780
×
290
Color
Fine snow
Stucco white
Net weight
kg
8.5
31
Refrigerant equipment
Compressor type & Q’ty
–
2PS146D5BC04 (Rotary type)
×
1
Motor
kW
–
0.7
Starting method
–
Line starting
Heat exchanger
Louver fins & inner grooved tubing
Straight fin & inner grooved tubing
Refrigerant control
Capillary tubes
Refrigerant
(3)
kg
R22
0.89 (Pre-Charged up to the piping length of 7m)
Refrigerant oil
R
0.32 (ATMOS NM56M or SUNISO 4GDID)
Deice control
Microcomputer control
Air handling equipment
Fan type & Q’ty
Tangential fan
×
1
Propeller fan
×
1
Motor
W
14
15
(Cooling)
8.5
29
Air flow (at High)
(Heating)
CMM
9.5
29
Air filter, Q’ty
Polypropylene net (washable)
×
2
–
Shock & vibration absorber
–
Cushion rubber (for compressor)
Electric heater
–
–
Operation control
Operation switch
Wireless-Remote control
–
Room temperature control
Microcomputer thermostat
–
Pilot lamp
RUN (Green), TIMER (Yellow), HI POWER (Green), ECONO (Orange)
Safety equipment
O.D
mm (in)
Liquid line:
φ
6.35 (1/4
″
)
Gas line:
φ
9.52 (3/8
″
)
Connecting method
Flare connecting
Attached length of piping
Liquid line: 0.4 m
Gas line : 0.33 m
–
Insulation
Necessary (Both sides)
Drain hose
Connectable
Power source cord
2 m (3 cores with Earth)
Size
×
Core number
1.5 mm
2
×
4 cores (Including earth cable)
Connection wiring
Connecting method
Terminal block (Screw fixing type)
Accessories (included)
Mounting kit, Clean filter (Natural enzyme filter
×
1, Photocatalytic washable deodorizing filter
×
1)
Optional parts
–
Notes (1) The data are measured at the following conditions.
Item
Indoor air temperature
Outdoor air temperature
Standards
Operation
DB
WB
DB
WB
Cooling
27ºC
19ºC
35ºC
24ºC
ISO-T1, JIS C9612
Heating
20ºC
–
7ºC
6ºC
ISO-T1, JIS C9612
(2) The operation data are applied to the 220/230/240V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 7 m connecting piping.
If the piping length is longer, when it is less than 10 m, add 20 g refrigerant per meter and when it is 10 to 15 m, add 30 g refrigerant per meter.
Operation data
(1)
Refrigerant
piping
Frost protection, Serial signal error protection
Fan motor error protection
The piping length is 7 m.
Compressor overheat protection, High pressure
control, Serial signal error protection
(220/230/240V)