EN-12
COOL/HEAT/DRY/FAN mode operation
Airflow direction adjustment procedure.
Page 13
4
3
To stop:
Press the ON/OFF button.
x
In case air is not blown out, when starting the heating
operation.
x
The operation mode can also be set or changed when the
air-conditioner is not in operation.
NOTE
2
1
Air-conditioner operation temperature range
■
Use within the following operational range. Operating outside of this range may result in the protection devices being activated and
preventing the unit from working.
Characteristics of HEAT mode operation
Mechanism and capacity of HEAT mode operation
x
The unit draws heat from the cold outside air, transfers it to indoors and heats the room. As a characteristic of heat pump system, the
heating capacity reduces when the outside air
temperature gets colder.
x
It may take some time to supply hot air after turning on the air-conditioner.
x
If the outside temperature becomes extremely low, it would be better to use an additional source of heating.
Defrosting
If the outside temperature becomes low and humidity is high, the heat exchanger in the outdoor unit may frost over, which prevents efficient heating.
If this happens, the automatic defrost function is activated and the heating operation stops for 5 to 15 minutes during defrosting.
x
Both indoor and outdoor fans stop and the RUN light blinks slowly (1.5 seconds ON, 0.5 seconds OFF) during defrosting.
x
The outdoor unit may release some steam during defrosting. This is to help the defrosting
process and is not a defect.
x
The HEAT operation resumes as soon as defrosting has been completed.
Press the FAN SPEED button
Set the fan speed as preferred.
A fan speed cannot be set under DRY operation.
Page 22
COOL
HEAT
DRY
FAN
26 °C - 28 °C
22 °C - 24 °C
24 °C - 26 °C
—
Press the MODE button.
Set to a required mode.
(COOL),
(HEAT), (DRY), (FAN)
Press the ON/OFF button.
Press the TEMP button.
Press
or
button for the preferred temperature.
Recommendation
COOL mode operation
HEAT mode operation
Outside temperature
Approximately -15 to 46 °C
Approximately -15 to 24 °C
Inside temperature
Approximately 18 to 32 °C
Approximately 10 to 30 °C
Inside humidity
Below approximately 80 %
The long-term use of the unit with a humidity level
exceeding 80 % may result in condensation forming
on the surface of the indoor unit, leading to water
drops.
RLC012A103_EN.indd 12
9/25/2018 11:57:41 AM