EN-17
HIGH POWER/ECONOMY operation
■
When the air-conditioner is turned off, start the operation from Step 1. When the air-conditioner is running, start from Step 2.
2
Press the ON/OFF button.
Press the HI POWER/ECONO button.
■
When the operating mode is AUTO, COOL or HEAT
Every time the HI POWER/ECONO button is pressed, the display is
switched in the order of:
(HIGH POWER)
(ECONOMY)
(Normal operation)
No display
■
When the operating mode is DRY or PROGRAM TIMER
Every time the HI POWER/ECONO button is pressed, the display is
switched in the order of:
No display
(ECONOMY)
(Normal operation)
1
Concerning ECONOMY operation
Pressing the HI POWER/ECONO button initiates a soft operation with the power suppressed in order to avoid an excessive cooling
or heating. The unit operates 1.5 °C higher than the setting temperature during cooling or 2.5 °C lower than that during heating. The
remote control displays
and the FAN SPEED display is disappeared.
NOTE
x
It will go into ECONOMY operation at the next time the
air-conditioner runs in the following case.
1
When the air-conditioner is stopped by ON/OFF button
during ECONOMY operation.
2
When the air-conditioner is stopped in SLEEP or OFF
TIMER operation during ECONOMY operation.
3
When the operation is retrieved from SELF CLEAN
operation.
x
When the following operations are set, ECONOMY operation
will be canceled.
1
When the HI POWER/ECONO button is pressed
again.
2
When the operation mode is changed from DRY to
FAN.
x
Not operable while the air-conditioner is OFF.
Concerning HIGH POWER operation
Pressing the HI POWER/ECONO button intensi
¿
es the operating power and initiates powerful cooling or heating operation for 15
minutes continuously. The remote control displays
and the FAN SPEED display is disappeared.
x
During the HIGH POWER operation, the room temperature
is not controlled. When it causes an excessive cooling or
heating, press the HI POWER/ECONO button again to cancel
the HIGH POWER operation.
x
HIGH POWER operation is not available during the DRY and
the program timer operations.
x
When HIGH POWER operation is set after ON TIMER
operation, HIGH POWER operation will start from the set time.
x
After HIGH POWER operation, the sound of refrigerant
flowing may be heard.
x
When the following operations are set, HIGH POWER operation
will be canceled.
1
When the HI POWER/ECONO button is pressed again.
(The operation mode will be changed to the
ECONOMY
operation)
2
When the operation mode is changed.
3
When it has been 15 min. since HIGH POWER operation
has started.
x
Not operable while the air-conditioner is OFF.
NOTE
RLC012A103_EN.indd 17
9/25/2018 11:57:42 AM
Summary of Contents for SRK25ZSP-W
Page 2: ......
Page 26: ...EN 24 ...