3
-
Item
Model
SRK40HD
SRC40HD
Cooling capacity
(1)
W
Heating capacity
(1)
W
Power source
1 Phase, 220/230/240V, 50Hz
Cooling input
kW
Running current (Cooling)
A
Heating input
kW
Running current (Heating)
A
Inrush current
A
COP
Cooling
sound level
Noise level
Power level
dB
(56)
(63)
Heating
sound level
Power level
(57)
(64)
Exterior dimensions
Height
×
Width
×
Depth
mm
250
×
815
×
249
640
×
850
×
290
Color
Cool white
Stucco white
Net weight
kg
9.0
41
Refrigerant equipment
Compressor type & Q’ty
–
(RM5517GNE4)
Motor
kW
–
1.3
Starting method
–
Line starting
Heat exchanger
Louver fins & inner grooved tubing
Refrigerant control
Capillary tubes
Refrigerant
(3)
kg
R22 (Pre-Charged up to the piping length of 7.5m)
Refrigerant oil
R
0.6 (BARREL FREEZE 32SAM)
Deice control
MC control
Air handling equipment
Fan type & Q’ty
Tangential fan
×
1
Propeller fan
×
1
Motor
W
14
35
(Cooling)
9.0
38
Air flow (at High)
(Heating)
CMM
9.5
38
Air filter, Q’ty
Polypropylene net (washable)
×
2
–
Shock & vibration absorber
–
Cushion rubber (for compressor)
Electric heater
–
–
Operation control
Operation switch
Wireless-Remote controller
–
Room temperature control
MC. Thermostat
–
Pilot lamp
RUN (Green), TIMER (Yellow), HI POWER (Green), ECONO (Orange)
Safety equipment
O.D
mm (in)
Liquid line:
φ
6.35 (1/4
″
)
Gas line:
φ
12.7 (1/2
″
)
Connecting method
Flare connecting
Attached length of piping
Liquid line: 0.4 m
Gas line : 0.33 m
–
Insulation
Necessary (Both sides)
Drain hose
Connectable
Power source cord
2.5 m (3 cores with Earth)
Size
×
Core number
1.5 mm
2
×
4 cores (Including earth cable)
Connection wiring
Connecting method
Terminal block (Screw fixing type)
Accessories (included)
Mounting kit
Optional parts
–
Notes (1) The data are measured at the following conditions.
Model SRK40HD (Indoor unit)
SRC40HD (Outdoor unit)
Item
Indoor air temperature
Outdoor air temperature
Standards
Operation
DB
WB
DB
WB
Cooling
27ºC
19ºC
35ºC
24ºC
ISO-T1, JIS C9612
Heating
20ºC
–
7ºC
6ºC
ISO-T1, JIS C9612
(2) The operation data are applied to the 220/230/240V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 7.5 m connecting piping.
If the piping length is longer, when it is less than 10 m, add 20 g refrigerant per meter and when it is 10 to 15 m, add 30 g refrigerant per meter.
Operation data
(1)
Refrigerant
piping
The piping length is 7.5m.
Frost protection, Serial signal error protection
Fan motor error protection
Compressor overheat protection, Overcurrent pro-
tection, Serial signal error protection