145
-
Item
Model
SRK40HC-S2
SRC40HC-S2
Cooling capacity
(1)
W
3600
Heating capacity
(1)
W
4000
Power source
1 Phase, 220–240V, 50Hz
Cooling input
kW
1.12
Running current (Cooling)
A
5.3/5.1/4.9
Heating input
kW
1.16
Running current (Heating)
A
5.5/5.3/5.1
Inrush current
A
25.2
COP (Cooling)
Cooling: 3.21 Heating: 3.42
Cooling
Sound level
42
51
Noise level
Power level
dB
56
63
Heating
Sound level
43
52
Power level
57
64
Exterior dimensions
Height
×
Width
×
Depth
mm
250
×
815
×
247
640
×
850
×
290
Color
Cool white
Stucco white
Net weight
kg
9.0
41
Refrigerant equipment
Compressor type & Q’ty
–
5KS150DBB [Rotary type]
×
1
Motor
kW
–
1.1
Starting method
–
Line starting
Heat exchanger
Louver fins & inner grooved tubing
Straight fins & inner grooved tubing
Refrigerant control
Capillary tubes + Electric expansion valve
Refrigerant
(3)
kg
R410A
1.17 (Pre-Charged up to the piping length of 15m)
Refrigerant oil
R
0.43 (RB68A)
Deice control
Microcomputer control
Air handling equipment
Fan type & Q’ty
Tangential fan
×
1
Propeller fan
×
1
Motor
W
14
35
(Cooling)
9.0
38
Air flow (at High)
(Heating)
CMM
9.5
38
Air filter, Q’ty
Polypropylene net (washable)
×
2
–
Shock & vibration absorber
–
Cushion rubber (for compressor)
Electric heater
–
–
Operation control
Operation switch
Wireless-Remote controller
–
Room temperature control
Microcomputer thermostat
–
Pilot lamp
RUN (Green), TIMER (Yellow), HI POWER (Green), ECONO (Orange)
Safety equipment
O.D
mm (in)
Liquid line:
φ
6.35 (1/4
″
)
Gas line:
φ
12.7 (1/2
″
)
Connecting method
Flare connecting
Attached length of piping
Liquid line: 0.4 m
Gas line : 0.33 m
–
Insulation
Necessary (Both sides)
Drain hose
Connectable
Power source cord
2.5 m (3 cores with Earth)
Size
×
Core number
1.5 mm
2
×
4 cores (Including earth cable)
Connection wiring
Connecting method
Terminal block (Screw fixing type)
Accessories (included)
Mounting kit, Clean filter (Natural enzyme filter x2)
Optional parts
–
Notes (1) The data are measured at the following conditions.
Model SRK40HC-S2 (Indoor unit)
SRC40HC-S2 (Outdoor unit)
(220/230/240V)
Item
Indoor air temperature
Outdoor air temperature
Standards
Operation
DB
WB
DB
WB
Cooling
27ºC
19ºC
35ºC
24ºC
ISO-T1, JIS C9612
Heating
20ºC
–
7ºC
6ºC
ISO-T1, JIS C9612
(2) The operation data are applied to the 220/230/240V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 15 m connecting piping.
(Purging is not required even in the short piping.)
Operation data
(1)
Refrigerant
piping
Compressor: Overheat protection, overcurrent protection, Serial signal error protection, Indoor fan
motor error protection
The piping length is 7.5m.
Summary of Contents for SRK56CE-S1
Page 138: ... 136 MEMO ...
Page 262: ... 260 MEMO ...