(11) Outline of automatic operation
(a)
Determination of operation mode
The unit checks the room temperature and the outdoor air temperature after operating the indoor and outdoor blowers for 20
seconds, determines the operation mode and the room temperature setting correction value, and then begins in the automatic
operation.
¡
Heat pump type
Heating
Dehumidifying
Cooling
Room temperature (˚C)
Outdoor temperature (˚C)
Room temperature (˚C)
¡
Cooling only type
Cooling
Dehumidifying
Outdoor temperature (˚C)
Compressor
and
outdoor fan
ON
OFF
OFF
Indoor fan
Start
Temperature check
Speed 4
4
8
0
Speed 1
20
seconds
minutes
B Block
Compressor
and
outdoor fan
ON
OFF
OFF
Indoor fan
Start
Temperature check
Speed 4
8
0
minutes
A Block
Compressor
and
outdoor fan
ON
OFF
OFF
Indoor fan
Start
Temperature check
4
8
0
Speed 1
20
seconds
minutes
20
seconds
D Block
Compressor
and
outdoor fan
ON
OFF
OFF
Indoor fan
Start
Temperature check
Speed 4
Speed 1
8
3
0
minutes
C Block
Operation block decision
Operation block decision
(c)
DRY operation
After finishing start up operation described in (b) previous page, thermal dry operation is performed at 8 minutes intervals,
according to the difference between room temperature and thermostat setting temperature as shown below.
Beside, 1 cycle of this operating time consists of 8 minutes, 7 cycle operation is performed then.
Running time
Running start ~ 1 hour
1~2 hours
2 hours ~
Set temperature compensation
Set tempe0.5
Set tempe1.0
Set tempe1.5
(d)
ECONOMY operation ( “ECONO” button on the remote control : ON)
The set temperature changes as shown at right, and the
indoor unit fan speed is set on speed 4 .