90
-
When the compressor is operating
When the compressor is stopped
(Including protection stoppage)
Inverter command speed
20 rps
0 rps
Indoor fan motor
OFF
Outdoor fan motor
3rd speed
Determined by heating stop mode
Flap and louver
Horizontal/ Center
4-way valve
ON
Determined by heating stop mode
(i)
Fan operation
1
1)
Operation content
Inverter command speed
0 rps
Indoor fan motor
1st speed
Outdoor fan motor
OFF
Flap and louver
Fully closed/ Center
(ii)
Cooling operation
1)
Operation content
Inverter command speed
20 rps
Indoor fan motor
2nd speed
Outdor fan motor
3rd speed
Flap and louver
Horizoc/Center
4-way valve
OFF
Note (1)
During cooling operation safety control,frost
prevention control, and cooling overload pro-
tective control are generally not applicable
(iii) Heating cycle operation
1)
Operation content
T
1
T
2
42min.
Time
Stop
Compressor operation
2)
Operation time
After cooling operation
(outdoor temperature–indoor
temperature)
T
1
(Compressor operation time)
T
2
(Compressor stopped time)
Heating operation control time (T
1
+T
2
)
–12
°
C
~
–10
°
C
80
2440
~
–12
°
C
90
2430
–10
°
C
~
–8
°
C
70
2450
–8
°
C
~
–6
°
C
60
2460
–6
°
C
~
–4
°
C
50
2470
42min.
–4
°
C
~
–2
°
C
40
2480
–2
°
C
~
0
°
C
30
2490
0
°
C
~
4
°
C
20
2500
4
°
C
~
9
°
C
10
2510
(Sec.)