78
-
'13 • SRK-T-144
'09•SRK-DB-087D
Outdoor fan motor error
Rotor lock
(8) Phenomenon observed after shortcircuit, wire breakage on sensor
(a) Indoor unit
Defective fan motor, connector poor
connection, defective outdoor PCB
Defective compressor, defective
outdoor PCB
Sensor
Operation
mode
Phenomenon
Shortcircuit
Disconnected wire
Room temperature
sensor
Cooling
Heating
Heat exchanger
sensor
Cooling
Heating
Humidity sensor
(1)
Cooling
Heating
■
Humidity sensor operation
Failure mode
Control input circuit resding
Air conditioning system operation
①
②
①②
①
②
See page 75.
Service valve (gas side) closed operation
Service valve (gas side) closed,
Defective outdoor PCB
Are the service valve (gas side)
opened ?
Open the valve.
NO
YES
NO
YES
Is the checked result of power
transistor module OK ?
Defective outdoor PCB
Replace.
Defective outdoor PCB
Replace.
NO
YES
YES
Is the space for installation of indoor and/or
outdoor unit enough ?
Is there any short circuit of air on indoor
and/or outdoor unit ?
At heating, does the indoor fan motor run ?
Is the filter clogged ?
Is there any liquid flooding ?
Is there any anomalous sound on the
compressor?
After resetting power for several
times does it become normal ?
Temporary noise may cause of anomaly.
If noise source can be found, take
countermeasure.
Limit switch anomaly
Defective limit switch, defective indoor
control PCB, Defective air inlet panel set
Is the air inlet panel set correctly?
Are limit switch OK ?
Defective indoor control PCB
Correction, re-set
Defective limit switch
Note(1) Check if the limit switch functions properly or not by seeing whether
the lamp continues to blink or can be reset by pressing the limit swit-
-ch by hand while the air inlet panel is removed.