(b) Detail of control in each mode (Pattern)
(i) Fuzzy operation
During the fuzzy operation, the air flow and the compressor speed are controlled by calculating the difference between
the indoor temperature setting correction temperature and the return air temperature.
12~86rps
12~86rps
12~62rps
12~34rps
SRK50ZMX-S
20~86rps
20~86rps
20~58rps
20~42rps
SRK35ZMX-S
20~74rps
20~74rps
20~55rps
20~38rps
SRK25ZMX-S
20~65rps
20~65rps
20~44rps
20~34rps
SRK20ZMX-S
Model
Fan speed
12~110rps
12~110rps
12~86rps
12~48rps
12~30rps
20~38rps
20~34rps
20~30rps
12~30rps
SRK60ZMX-S
Auto
MED
HI
LO
ULO
(17) Outline of automatic operation
Heating
Dehumidifying
Cooling
Indoor air temperature (˚C)
Outdoor air temperature (˚C)
(a) Determination of operation mode
The unit checks the indoor air temperature and the outdoor air temperature, determines the operation mode, and then begins
in the automatic operation.
(16) Outline of dry (dehumidifying) operationion
(a) Purpose of DRY mode
The purpose is "Dehumidification", and not to control the humidity to the target condition.
Indoor/outdoor unit control the operation condition to reduce the humidity, and also prevent over cooling.
(b) Outline of control
(i)
Indoor unit fan speed and compressor are controlled by the area which is selected by the temperature difference.
(ii)
The indoor unit check the current area by every 5 minutes, and operate by the next checking.
(c) Other
When the outside temperature and room temperature is low for cooling operation, indoor unit can not operate in cooling,
and dehumidify. In this case, the units operate in heating to rise the room temperature, and after that start DRY operation.
Indoor unit fan speed
Area
D
C
B
A
Me speed
Indoor unit
fan speed
ULo(Lo) speed
STOP
Limited
䋨
Lower than
normal cooling operation
䋩
Compressor
Limited
speed
Minimum
䋨
Lower than the speed in ”Area A”
䋩
STOP
set temperature
Difference between set temperature and return temperature