141
-
'17 • SCM-T-225
(8) Eco operation
Pressing the HI POWER/ECONOMY button initiate a soft operation with the power suppressed in order to avoid an excessive cooling
or heating. The unit operate 1.5
℃
higher than the setting temperature during cooling or 2.5
℃
lower than that during heating. The
wireless remote control displays ECONOMY mark and the FAN SPEED display disappears.
(a) It will go into ECONOMY operation at the next time the air-conditioner runs in the following cases.
①
When the air-conditioner is stopped by ON/OFF button during ECONOMY operation.
②
When the air-conditioner is stopped in SLEEP or OFF TIMER operation during ECONOMY operation.
③
When the operation is retrieved from CLEAN or ALLERGEN CLEAR operation.
(b) When the following operation are set, ECONOMY operation will be cancelled.
①
When the HI POWER/ECONOMY button is pressed again.
②
When the operation mode is changed from DRY to FAN.
③
When the NIGHT SETBACK botton is pressed.
(c) Not operable while the air-conditioner is OFF.
(d) The setting temperature is adjusted according to the following table.
①
at the start of operation.
②
one hour after the start of operation.
③
two hours after the start of operation.
Temperature
adjustment
Cooling
Heating
①+0.5
①-1.0
②+1.0
②-2.0
③+1.5
③-2.5
Mode
Item
Notes (1) It will go into economy operation at the next time the air-conditioner runs in the following case.
①
When the air-conditioner is stopped by ON/OFF button during economy operation.
②
When the air-conditioner is stopped in SLEEP or OFF TIMER operation during economy operation.
③
When the operation is retrieved from SELF CLEAN or ALLERGEN CLEAR operation.
(2) When the following operations are set, economy operation will be cancelled.
①
When the HI/ECO button is pressed again.
②
When the operation mode is changed from DRY to FAN.
③
When the NIGHT SETBACK button is pressed.
(3) Not operable while the air-conditioner is OFF.
'09•SRK-DB-087D
(9)
Air flow direction adjustment
(a) Flap
(b) Louver
(c) Swing
(i)
(ii)
(d) Memory flap (Flap or louver stopped)
COOL, DRY, FAN
Wireless remote
control display
HEAT
Approx. 15°
Approx. 30°
Approx. 40°
Approx. 25°
Approx. 45°
Approx. 55°
(Swing)
(Flap stopped)
Approx. 30°
Approx. 50°
Approx. 55°
Angle of flap from horizontal
Center installation
Wireless remote
control display
Right end installation
Left end installation
Angle of louver
Center
Left approx. 30°
Right approx. 20°
Center
Right approx. 50°
Right approx. 20°
Right approx. 30° Right approx. 45° Right approx. 50°
(Louver stopped)
(Swing)
(Spot)
(Wide)
In HEAT operation
In COOL, DRY, FAN operation
Approx. 30°
Approx. 55°
Approx.
25°
Approx. 55°
Air flow direction can be adjusted with by AIR FLOW U/D (UP/DOWN) and L/R (LEFT/RIGHT) button on the
wireless remote control.
Every time when you press the AIR FLOW L/R
Left approx. 50°
Left approx. 50°
Left approx. 20°
Left approx. 20°
Left approx. 45°
Center
Approx. 20°
COOL/DRY
HEAT
Set
temperature
Heat Source & Movement
COOL/DRY
HEAT
Set
temperature
(a) Pressing the HI/ECO button initiates a soft operation with the power suppressed in order to avoid an excessive cooling or heating.
(b) The remote control
displays.
(c) The set temperature will be adjusted according to the amount of movement made by the person(s) the motion sensor has detected.
MODE:AUTO mode operation
MODE:COOL/HEAT/DRY mode operation
Low
When the extent of human
movement is low
High
When the extent of human
movement is high
None
When there is no one in the
room
• The set temperature is automatically adjusted
during economy operation, however, the
indication on the remote control display does
not change.
• When the SLEEP TIMER, OFF TIMER,
and ON TIMER + OFF TIMER operation
are set, the motion sensor does not adjust
temperatures.
+2ºC
-2ºC
+3ºC
-3ºC
+3ºC
-3ºC
Low
Normal
High
None
Heat Source & Movement
Low
Normal
High
None