36
-
'17 • SCM-T-225
Operation data
Nominal cooling capacity (range) kW
6.0
Nominal heating capacity (range)
kW
6.8
Sound power level
Cooling
dB(A)
60
Heating
63
Sound pressure level
①
Cooling
Hi: 44 Me: 38 Lo: 35 ULo: 30
Heating
Hi: 45 Me: 41 Lo: 38 ULo: 33
Sound pressure level
②
Cooling
Hi: 37 Me: 34 Lo: 32 ULo: 27
Heating
Hi: 39 Me: 37 Lo: 34 ULo: 29
Sound pressure level
③
Cooling
Hi: 42 Me: 39 Lo: 36 ULo: 30
Heating
Hi: 47 Me: 44 Lo: 41 ULo: 35
Silent mode sound pressure level
—
Exterior dimensions (Height x Width x Depth)
mm
200 x 950 x 500
Exterior appearance
( Munsell color )
—
Net weight
kg
24
Heat exchanger
Louver fins & inner grooved tubing
Fan type & Q'ty
Centrifugal fan x 3
Fan motor (Starting method)
W
85 x1 (Direct drive)
Air flow
Cooling
m
3
/min
Hi: 14.5 Me: 11.5 Lo: 10.5 ULo: 8.0
Heating
Hi: 15.0 Me: 13.0 Lo: 11.5 ULo: 9.0
Available external static pressure
Pa
50 (Initial static pressure with air filter:5Pa)
Outside air intake
Not possible
Air filter, Quality / Quantity
Polypropylene net x 1
Shock & vibration absorber
Cushion rubber (for fan motor)
Operation control
Remote control
Wireless remote control
Room temperature control
Microcomputer thermostat
Operation display
RUN: Green, TIMER: Yellow, HI POWER: Green, ECONO: Green
Safety equipments
Drain error protection, Frost protection, Serial signal error protection,
Indoor fan motor error protection
Installation data
Refrigerant piping size ( O.D )
mm
Liquid line:
φ
6.35 ( 1/4" ) Gas line:
φ
12.7 ( 1/2" )
Connecting method
Flare connection
Insulation for piping
Necessary (Both sides), independent
Drain hose
Hose connectable ( VP25 )
Drain pump, max lift height
mm
Built-in, MAX600
Interconnecting wires
Size x Core number
1.5mm
2
x 4 cores ( Including earth cable ) / Terminal block ( Screw fixing type )
IP number
IPX0
Standard accessories
Mounting kit, Joint for drain piping
Option parts
Wired remote control, Interface kit ( SC-BIKN2-E ), Bottom air inlet kit
Model
Item
SRR60ZM-S
Power source
1 Phase, 220−240 V, 50Hz
①
②
③
External static
pressure
for
②
,
③
:
10Pa
Notes (1) The data are measured at the following conditions.
Item
Operation
Indoor air temperature Outdoor air temperature
Standards
Note
DB
WB
DB
WB
Cooling
27˚C
19˚C
35˚C
24˚C
ISO5151-T1
Non-duct
(with air fillter)
Heating
20˚C
—
7˚C
6˚C
(2) This air-conditioner is manufactured and tested in conformity with the ISO.
(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat
higher due to ambient conditions.
The pipe length is 5m.
(4) Mike positions of measureing
sound pressure level of indoor
unit is shown below.
A
RWA000Z263