60
-
'17 • SCM-T-225
(4) 4 way ceiling cassette type (FDTC)
Models FDTC25VF, 35VF, 50VF, 60VF
Contr
ol PCB
Power PCB
XR1
XR2
XR3
XR4
XR5
(
Remote operation input:volt-fr
ee contact
)
Option
1
2
3
4
5
6
+12
SW2
SW6
SW5
SW7
LED
・
2
LED
・
3
X
Y
1
3
X
Y
t°
Remote contr
ol
TB2
WH
BK
CNW3
RD
CNW2
RD
CNW4
BL
CNW1
BL
CNB
WH
CNN
Y
CNH
BK
CNI
BL
CNT
BL
1
2
WH
RD
F200
(
3.15A
)
F201
(
3.15A
)
F202
(
1.0A
)
F203
(
0.16A
)
X4
5
3
CNW0
WH
7
TB1
CNJ
WH
(Operation) (Heating) (Compressor ON) (Inspection)
Ear
th
Y
/
GN
Y
/
GN
Th
C
1
3
M
1
~
CNR
WH
DM
WH
BR
Y
Y
2
1
CNR2
BL
M
1
4
5
6
7
CNM
WH
FM
i
5
6
4
3
2
RD
BL
BR
OR
WH
RD
BL
BR
OR
WH
5
6
4
3
2
RD
BL
BR
OR
WH
CNM3
RD
CNM4
WH
BK
t°
BK
BK
t°
BK
1
2
1
2
BK
t°
BK
3
4
Th
i
-R2
Th
i
-R3
Th
i
-A
BL
BL
RD
RD
Y
Y
CNH2
WH
BK
t°
BK
5
6
Th
i
-R1
BK
BK
CNN2
BK
RD
RD
1
2
FS
WH
WH
CNI2
WH
3
4
5
6
7
8
9
10
1
2
1
2
3
4
5
6
1
2
1
2
BL
BL
RD
RD
Y
Y
BK
BK
WH
WH
CNC
WH
Power cir
cuit
Y
/
GN
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
M
LM1
M
LM2
M
LM3
M
LM4
1
2
3
4
5
BK
BK
BK
BK
BK
CNJ2
WH
2
1
3
4
5
1
2 3
4
5
BL
BL
BL
BL
BL
1
2
3
4
5
RD
RD
RD
RD
RD
1
2
3
4
5
3
Power sour
ce line
Signal line
1
2
3
[
]
indoor unit and outdoor unit
Connecting line between
BL
1
Y
/
GN
Y
/
GN
Y
/
GN
6
7
8
9
BK
BK
BK
BK
10
BK
11
BK
12
BK
13
BK
14
BK
15
BK
16
BK
17
BKBK
18
BK
19
BK
20
BK
1
2
3
4
5
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BKBK
BK
BK
BK
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
i
FS
LM1
-
4
DM
FM
Float switch
Drain motor
Fan motor
Louver motor
Indication lamp
(
Red-Inspection
)
Indication lamp
LED
・
3
F200
-
203
Fuse
LED
・
2
Connector
CNB
-
Z
(
Gr
een-Nor
mal operation
)
Model capacity setting
SW6
Operation check,Drain motor test run
SW7-1
SW5
Ther
mistor
(
Remote contr
ol
)
Ther
mistor
(
Heat exchanger
)
Ther
mistor
(
Retur
n air
)
Thc
Th
i
-R1,2,3
Th
i
-A
TB2
Ter
minal block
(
Signal line
)(
□
mark
)
Relay for DM
X4
■
mark
Closed-end connector
TB1
Ter
minal block
(
Power sour
ce
)
(
□
mark
)
Remote contr
ol communication
SW2
Orange
OR
BR
Br
own
BK
Black
Blue
Color marks
Meaning of marks
BL
Mark
Color
Red
RD
Y
Y
/
GN
WH
Yellow
Yellow
/
Gr
een
White
Plural units Master
/
Slave setting
addr
ess
Notes 1. indicates wiring on site.
3. See the wiring diagram of outside unit about the line between
4. Use twin cor
e cable
(
0.3mm X2
)
at r
emote contr
ol line.
2
inside unit and outside unit.
2. TB1 is the ter
minal block for heavy curr
ent
(
connecting line between
and TB2 is the ter
minal block for weak curr
ent
(
remote contr
ol
)
.
indoor unit and outdoor unit
)
,
5. Do not put r
emote contr
ol line alongside power sour
ce line.
D
PJA003Z340