15
-
'19 • SCM-SM-276
(19) Protective control function
(a) Dew prevention control [Cooling]
Prevents dewing on the indoor unit.
(i) Operating conditions
When the following conditions have been satisfied for more than 30 minutes after starting operation
1) The compressor is ON.
2) Detected value of humidity is 68% (models SRK50, 60: 60%) or higher.
(ii) Contents of operation
1) Air capacity control
Model
Item
SRK20, 25ZSX-W
SRK35ZSX-W
SRK50, 60ZSX-W
Indoor fan
ULO
4th speed
AUTO, HI, MED, LO
Adaptable to compressor speed
'09•SRK-DB-087D
(18)
Outline of cooling operation
(a)
ࠉ
Operation of major functional components in cooling mode
(d) Countermeasure for excessive temperature rise
If it feels excessive temperature rise in heating operation, setting temperature can be lower.
ON
OFF
OFF
OFF
OFF
OFF
ON
OFF
(few minutes ON)
OFF
(few minutes ON)
ON
ON
OFF
Thermostat ON
Thermostat OFF
Failure
Cooling
Compressor
Indoor fan
Outdoor fan
4-way valve
(b) Detail of control in each mode (Pattern)
(i) Fuzzy operation
12-74rps
12-74rps
12-54rps
12-42rps
SRK35ZSX-S
12-86rps
12-86rps
12-70rps
12-50rps
SRK50ZSX-S
12-58rps
12-58rps
12-38rps
12-34rps
SRK25ZSX-S
12-50rps
12-50rps
12-34rps
12-30rps
SRK20ZSX-S
Model
Fan speed
Auto
MED
HI
LO
12-30rps
12-30rps
12-30rps
12-30rps
ULO
(b)
(i)
(ii)
(iii)
(c)
(d)
27.5
25.5
18.0
18
30
(18)
ࠉ
Outline of automatic operation
(a)
Determination of operation mode
Heating
Dehumidifying
Cooling
Indoor air temperature (˚C)
Outdoor air temperature (˚C)
Signals of wireless remote control (Display)
–6
–5
–4
–3
–2
–1
±
0
+1
+2
+3
+4
+5
+6
Setting
temperature
Cooling
Dehumidifying
Heating
A
When both the indoor and the outdoor air temperatures are in the range “A”, cooling or heating is switched depending on
the difference between the setting temperature and the indoor air temperature.
When the operation mode has been judged following the change of setting temperature with the remote control, the hourly j-
udgment of operation mode is cancelled.
12-54rps
12-70rps
12-110rps
12-110rps
12-90rps
12-66rps
SRK60ZSX-S
12-30rps
12-90rps
12-38rps
12-34rps
ECO
Heating
Cooling
SP: Setting temperature
SP
Indoor air
temperature (˚C)
28
Outdoor air temperature (˚C)
(b) Operation mode is changes when keep cooling and heating thermostat off 20 minutes and be satisfied following
conditions.
If the setting temperature is changed with the remote control, the operation mode is judged immediately.
(c) When the unit is started again within one hour after the stop of automatic operation or when the automatic operation is
selected during heating, cooling or dehumidifying operation, the unit is operated in the previous operation mode.
(d) Setting temperature can be adjusted within the following range. There is the relationship as shown below between the signals
of the wireless remote control and the setting temperature.
※
It can not be changed to heating mode if outdoor air temperature is 28
℃
or higher.
Heating
SP: Setting temperature
Indoor air temperature
−
Setting temperature (˚C)
Keep operation
mode
Cooling
Signals of wireless remote control (Display)
18
19
20
21
22
23
24
25
26
27
28
29
30
18
19
20
21
22
23
24
25
26
27
28
29
30
18
19
20
21
22
23
24
25
26
27
28
29
30
Setting
temperature
Cooling
Heating
SP
+
1
SP
−
1
Unit :
℃
Operation mode is determined by indoor air temperature and outdoor air temperature as following.
(a) Determination of operation mode
2) When this control has continued for more than 30 minutes continuously,the following wind direction control is performed.
a)
When the vertical wind direction is set at other than the vertical swing,the flaps change to the horizontal position.
b)
When the horizontal wind direction is set at other than the horizontal swing,the louver changes to the vertical position.
(iii) Reset condition
Humidity is less than 63% (models SRK50, 60: 55%).
Summary of Contents for SRK60ZSX-W