66
-
'19 • SCM-SM-276
(i)
Power saving
/
comfort control
The set temperature is adjusted according to the presence of people and their amount of activity detected by the infrared (motion)
sensor.
(ii) Auto-off control
When no activity is detected for 1 hour, unit will go stand-by mode.
※
Unit will re-start operation automatically with the
original set temperature by activity detection during the stand-by mode. When stand-by mode continues for 12 hours,
unit stops.
※
Compressor keeps stopped regardless of the set temperature.
Notes (1) When the following operations are set, power saving control will be canceled.
①
Energy-saving, Home leave mode, Warm-up control, Cooling operation check.
②
When the operation mode is changed DRY or FAN.
(2) Not operable while the air-conditioner is OFF.
Low
When the extent of human
activity is low
High
When the extent of human
activity is high
None
When there is no one in the
room
• When the “None” continues for 1 hour, the
FAN SPEED is set Lo.
MODE:AUTO/COOL/HEAT mode operation
COOL
HEAT
Set
temperature
-3ºC
33ºC
15ºC
+3ºC
Heat Source & Activity
Low
Normal
High
None
Summary of Contents for SRK60ZSX-W