– 32 –
At the end of the season
At the beginning of the season
Stop the unit and turn off the power source.
The unit consumes approx. 4W even when the unit is not operating.
Turning off the power source will help saving energy consumption and cost.
Ensure that the earth wiring is not snapped nor
disconnected.
Make sure that there are no obstacles blocking
the airflow around the air intake and outlet
openings of the indoor and outdoor units.
NOTE
Cooling/heating is affected by an air filter clogged up with dust etc., and the operation noise becomes louder. It
may also use extra electricity. Please clean the air filter at appropriate intervals.
1
2
Remove batteries from the remote control.
Clean both the indoor and outdoor units.
Clean and reinstall the air filters.
Perform the fan operation for 2 to 3 hours.
Dry the inside of the unit.
3
4
5
Make sure that there is no corrosion or rust on
the base frame of the outdoor unit.
Insert batteries in the remote control.
Turn on the power source.
3
2
1
4
5
Installing, inspecting and replacing the air-cleaning filter
1. Open the air inlet panel and remove the air filters.
Page 30
2. Remove the allergen clear filter (Light orange) from air-conditioner and inspect the
filter. Use a vacuum cleaner to remove any dust or dirt from the allergen clear filter.
Replace the allergen clear filter if it cannot be cleaned or if it has been for about
1 year.
(The allergen clear filter should be replaced after about 1 year of used. However, the
actual replacement period may vary depending on the conditions in which the filter
is used.)
Remove the photocatalytic washable deodorizing filter (orange) from air-conditioner
and inspect the filter. Periodically, remove any dust or dirt from the photocatalytic
washable deodorizing filter. If the photocatalytic washable deodorizing filter is
particularly dirty, it may be washed with water. However, the filter is fragile, so do
not scrub it with excessive force. After washing the filter, place it in sunlight to dry.
Placing the filter in sunlight restores the deodorizing effect.
3. Install the air-cleaning filter in the air-conditioner.
NOTE
•
The allergen clear filter and the photocatalytic washable deodorizing filter
may be installed on either the right or left side of the air-conditioner.
•
Install the allergen clear filter with the light orange side on front side.
•
The heat exchanger may injure your fingers.
•
Stand firmly on a stepladder or other stable object when removing the air inlet panel and filters.
Item
Feature
Color
For replacing the air-cleaning filter, contact your dealer.
The power of enzyme is used to eliminate allergy-
causing allergens that accumulate on the filter.
Sources of odors on the filter are broken up, resulting in
a deodorizing effect.
Photocatalytic washable
deodorizing filter
Orange
Allergen clear filter
Light orange
CAUTION
4. Install the air filters and close the air inlet panel.
Page 30
Air-cleaning filter
Panel
(air-conditioner)
RLF012A203_EN_1-36.indd 32
RLF012A203_EN_1-36.indd 32
7/28/2017 3:13:57 PM