– 35 –
Contact your dealer
■
Turn off the power switch immediately and inform your dealer in any of the following situations:
•
The fuse or switch blows continuously.
•
The cable becomes extremely hot.
The covering of the cable is cracked.
•
The TV, radio or other equipment starts to malfunction.
•
A switch does not activate properly.
•
A strange noise is heard during operation.
•
When abnormalities occur, turn off the power source immediately and turn it on after 3 minutes. Restart the operation with ON/OFF
button of the remote control and the abnormalities still continue.
•
The RUN and TIMER lights on the unit display section blink quickly (0.5 seconds ON; 0.5 seconds OFF) or the lights do not work.
About the multiple air-conditioners
Refrigerant (oil) recovery operation
• The air-conditioners cannot be in different operating modes at the same time, such as one unit being in the “Cool” mode and one
unit being in the “Heat” mode.
• When conducting different operations, the air-conditioner that was operated first will be given priority, so the air-conditioner that is
operated after that will conduct air blowing operation.
• When you want to give priority to the air-conditioner that was started later, either stop the air-conditioner that has priority or change
the operation type of the unit operated first to match that of the unit operated second.
• When other indoor units are operating in different modes, the RUN light illuminates.
• When the remote control operation switch is in the AUTO mode, the air-conditioner automatically selects either COOL or HEAT
mode when operation is started depending on the room temperature.
• During simultaneous operation of air-conditioners, operation modes may be automatically changed in response to the temperatures
of the individual rooms; this will result in the operation of the outdoor unit being stopped. In such a case, COOL or HEAT mode should
be used instead of AUTO mode. (This is only relevant when more than one air-conditioner unit is being used.)
• If the all of the indoor units are not operated at the same time for an extended period, the cooling or heating performance may
temporarily decrease. This is in order to control the recovery of the refrigerant (oil) in the stopped indoor unit(s). At this time, the
sound of refrigerant flowing may be heard from the stopped indoor unit(s).
Simultaneous Operation
Automatic Operation
ON
OFF
0.5 seconds
0.5 seconds
Auto restart function
■
Auto restart function records the operational status of the air-conditioner immediately prior to be switched off by a power cut, and then
automatically resumes operations after the power has been restored.
■
The following settings will be canceled:
1
Timer settings
2
HIGH POWER operations
•
Auto restart function is set at on when the air-conditioner is shipped from the factory. Consult with your dealer if this function needs
to be switched off.
•
When power failure occurs, the timer setting is canceled. Once power is resumed, set the timer again.
NOTE