24
-
'19 • SCM-SM-276
'09•SRK-DB-087D
(b)
(i)
(ii)
(iii)
(c)
(d)
27.5
25.5
18.0
18
30
(17)
Outline of cooling operation
(a)
ࠉ
Operation of major functional components in cooling mode
(d) Countermeasure for excessive temperature rise
If it feels excessive temperature rise in heating operation, setting temperature can be lower.
ON
OFF
OFF
OFF
OFF
OFF
ON
OFF
(few minutes ON)
OFF
(few minutes ON)
ON
ON
OFF
Thermostat ON
Thermostat OFF
Failure
Cooling
Compressor
Indoor fan motor
Outdoor fan motor
4-way valve
(17)
ࠉ
Outline of automatic operation
(a)
Determination of operation mode
Heating
Dehumidifying
Cooling
Indoor air temperature (˚C)
Outdoor air temperature (˚C)
Signals of wireless remote control (Display)
–6
–5
–4
–3
–2
–1
±
0
+1
+2
+3
+4
+5
+6
Setting
temperature
Cooling
Dehumidifying
Heating
A
When both the indoor and the outdoor air temperatures are in the range “A”, cooling or heating is switched depending on
the difference between the setting temperature and the indoor air temperature.
When the operation mode has been judged following the change of setting temperature with the remote control, the hourly j-
udgment of operation mode is cancelled.
(e)
When the unit is operated automatically with the wired remote control connected, the cooling operation is controlled according to
the display temperatures while the setting temperature is compensated by 1 during dehumidifying or by 2 during heating.
(b) Detail of control in each mode (Pattern)
(i) Fuzzy operation
20-98rps
20-98rps
20-80rps
20-76rps
SRK35ZS-S
23-96rps
23-96rps
23-62rps
23-46rps
SRK50ZS-S
20-74rps
20-74rps
20-55rps
20-48rps
SRK25ZS-S
20-66rps
20-66rps
20-44rps
20-38rps
20-38rps
23-37rps
20-38rps
20-30rps
SRK20ZS-S
Model
Fan speed
Auto
MED
ULO
HI
LO
Heating
Cooling
SP: Setting temperature
SP
Indoor air
temperature (˚C)
28
Outdoor air temperature (˚C)
(b) Operation mode is changes when keep cooling and heating thermostat off 20 minutes and be satisfied following
conditions.
If the setting temperature is changed with the remote control, the operation mode is judged immediately.
(c) When the unit is started again within one hour after the stop of automatic operation or when the automatic operation is
selected during heating, cooling or dehumidifying operation, the unit is operated in the previous operation mode.
(d) Setting temperature can be adjusted within the following range. There is the relationship as shown below between the signals
of the wireless remote control and the setting temperature.
(e) When the unit is operated automatically with the wired remote control, the cooling operation is controlled according to
the display temperatures while the setting temperature is compensated by
+
2
℃
during heating.
※
It can not be changed to heating mode if outdoor air temperature is 28
℃
or higher.
Heating
SP: Setting temperature
Indoor air temperature
−
Setting temperature (˚C)
Keep operation
mode
Cooling
Signals of wireless remote control (Display)
18
19
20
21
22
23
24
25
26
27
28
29
30
18
19
20
21
22
23
24
25
26
27
28
29
30
20
21
22
23
24
25
26
27
28
29
30
31
32
Setting
temperature
Cooling
Heating
SP
+
1
SP
−
1
Unit :
℃
(16)
Outline of dehumidifying (DRY) operation
The purpose is "Dehumidification", and not to control the humidity to the target condition.
Indoor/outdoor unit control the operation condition to reduce the humidity, and also prevent over cooling.
(i) Indoor unit fan speed and compressor are controlled by the area which is selected by the temperature difference.
Indoor unit fan speed
Area
D
C
B
A
Me speed
Indoor unit
fan speed
ULo(Lo) speed
Stop
Limited
(
Lower than
normal cooling operation
)
Compressor
Limited
speed
Minimum
(
Lower than the speed in”Area A”
)
Stop
Setting temperature
Difference between set temperature and indoor air temperature
When the outdoor air temperature and room temperature is low in cooling operation, indoor unit can not operate in cooling,
and dehumidify. In this case, the units operate in heating to rise the indoor air temperature and after that start DRY operation.
(a) Purpose of DRY mode
(b) Outline of control
(ii) The indoor unit check the current area by every 5 minutes, and operate by the next checking.
(c) Other
Operation mode is determined by indoor air temperature and outdoor air temperature as following.
(a) Determination of operation mode