59
-
'13 • SRK-T-147
(5) Selection of the annual cooling function
(a) The annual cooling function can be enabled or disabled by means
of the jumper wire (J172) on the indoor unit PCB and the dip switch
(SW2-4) on the interface kit (optional) PCB.
Note: (1) Default states of the jumper wire (J172) and the interface kit at the shipping from factory –On the
PCB, the dip switch (SW2-4) is set to enable the annual cooling function.
(2) To cancel the annual cooling setting, consult your dealer.
(b) Content of control
(i)
If the outdoor air temperature sensor (TH2) detects below 5°C, the indoor fan
speed is switched to 9th step. (It is not possible to change.)
(ii)
If the outdoor air temperature sensor (TH2) detects higher than 7°C, the indoor
fan speed is changed to the normal control speed.
Jumper wire
(J172)
Interface kit
(SC-BIKN-E)
SW2-4
Function
Shorted
ON
Enabled
Shorted
OFF
Disabled
Open
ON
Disabled
Open
OFF
Disabled
Jumper wire (J172)
ON
5
7
OFF
Outdoor air temperature ( C)
(6) High power operation
Pressing the HI/ECO button intensifies the operating power and initiates powerful cooling and heating operation for 15 minutes
continuously. The wireless remote control displays and the FAN SPEED display disappears.
(a)
During the HIGH POWER operation, the room temperature is not controlled. When it causes an excessive cooling and heating,
press the HI/ECO button again to cancel the HIGH POWER operation.
(b) HIGH POWER operation is not available during the DRY and the program timer operations.
(c) When HIGH POWER operation is set after ON TIMER operation, HIGH POWER operation will start from the set time.
(d) When the following operation are set, HIGH POWER operation will be canceled.
①
When the HI/ECO button is pressed again.
②
When the operation mode is changed.
③
When it has been 15 minutes since HIGH POWER operation has started.
④
When the 3D AUTO botton is pressed.
⑤
When the SILENT botton is pressed.
⑥
When the NIGHT SETBACK botton is pressed.
(e) Not operable while the air conditioner is OFF.
(f) After HIGH POWER operation, the sound of refrigerant flowing may be heard.
(7) Economy operation
Pressing the HI/ECO button initiate a soft operation with the power suppressed in order to avoid an excessive cooling or heating.
The unit operate 1.0
℃
higher than the setting temperature during cooling or 2.0
℃
lower than that during heating. The wireless
remote control displays ECONO mark and the FAN SPEED display disappears.
(a) It will go into ECONOMY operation at the next time the air conditioner runs in the following cases.
①
When the air-conditioner is stopped by ON/OFF button during ECONOMY operation.
②
When the air-conditioner is stopped in SLEEP or OFF TIMER operation during ECONOMY operation.
③
When the operation is retrieved from CLEAN or ALLERGEN CLEAR operation.
(b) When the following operation are set, ECONOMY operation will be canceled.
①
When the HI/ECO button is pressed again.
②
When the operation mode is changed DRY to FAN.
③
When the NIGHT SETBACK botton is pressed.
(c) Not operable while the air-conditioner is OFF.
(d) The setting temperature is adjusted according to the following table.
①
at the start of operation.
②
one hour after the start of operation.
③
two hours after the start of operation.
Temperature
adjustment
Cooling
Heating
①+0.5
①-1.0
②+1.0
②-2.0
③
③
Mode
Item
Summary of Contents for SRK63ZMA-S
Page 2: ......
Page 3: ... 13 SRK T 147 TECHNICAL MANUAL ...
Page 11: ... 13 SRK T 147 2 Outdoor units Models SRC63ZMA S 71ZMA S RCR000Z008 ...
Page 12: ... 10 13 SRK T 147 Model SRC80ZMA S RCR000Z009 ...
Page 13: ... 11 13 SRK T 147 Model SRC92ZMA S RCR000Z010 ...
Page 14: ... 12 13 SRK T 147 3 Remote control a Wireless remote control Unit mm 60 26 167 ...
Page 55: ... 53 13 SRK T 147 page 42 Model SRC92ZMA S ...
Page 56: ... 54 13 SRK T 147 ...
Page 57: ... 55 13 SRK T 147 ...
Page 58: ... 56 13 SRK T 147 ...
Page 108: ... 106 13 SRK T 147 3 Super link E board SC ADNA E F ...
Page 109: ... 107 13 SRK T 147 ...
Page 110: ... 108 13 SRK T 147 ...
Page 115: ... 113 13 SRK T 147 ...
Page 121: ... 119 13 SRK T 147 ...
Page 127: ... 125 13 SRK T 147 ...
Page 133: ... 131 13 SRK T 147 ...
Page 148: ... 146 13 SRK T 147 CRBE0347 5 14 15 13 13 15 16 2 3 4 6 12 15 9 10 7 11 15 15 8 1 PANEL ASSY ...