62
-
'13 • SRK-T-147
'09•SRK-DB-087D
(9) 3D auto operation
(a) During Cooliong and Heating (Including auto cooling and heating)
(i)
(ii)
Cooling
Air flow selection
Operation mode
AUTO
Heating
Indoor temp. – Setting temp. >5°C
Indoor temp. – Setting temp. 5°C
Setting temp. – Indoor temp. >5°C
Setting temp. – Indoor temp. 5°C
HIGH POWER
AUTO
HI
HI
MED
MED
ULO
ULO
LO
LO
HIGH POWER
AUTO
<
=
<
=
Flap
Louver
Cooling
Up/down swing
Heating
Wide (Fixed)
Center (Fixed)
Flap
Louver
Cooling
Heating
Left/right swing
Horizontal blowing (Fixed)
Slant forward blowing (Fixed)
Flap
Louver
Cooling
Up/down swing
Heating
Center (Fixed)
Wide (Fixed)
Flap
Louver
Cooling
Heating
Horizontal blowing (Fixed)
Slant forward blowing (Fixed)
Operation mode
Indoor temp. – Setting temp. 2°C
Setting temp. – Indoor temp. 2°C
Heating
Cooling
Air flow direction contorol
2°C < Setting temp. – Indoor temp. 5°C
2°C < Indoor temp. – Setting temp. 5°C
Indoor temp. – Setting temp. > 5°C
Setting temp. – Indoor temp. > 5°C
The control in 4) continues.
Control returns to the control in 2).
Control returns to the control in 1).
The control in 4) continues.
Control returns to the control in 2).
Control returns to the control in 1).
<
=
<
=
<
=
<
=
Wide (Fixed)
Flap
Louver
Horizontal blowing (Fixed)
1)
2)
3)
4)
5)
3
4
(b) During DRY Operation (including auto DRY operation)
'09•SRK-DB-087D
(b) Sleep timer operation
(10)
Timer operation
(a) Comfortable timer setting (ON timer)
(c) OFF timer operation
(13)
Installation location setting
(a) Setting
(i) If the air conditioning unit is running, press the ON/OFF button to stop.
(ii) Press the AIR FLOW U/D (UP/DOWN) button and the
AIR FLOW L/R (LEFT/RIGHT) button together for 5 seconds
or more.
(iii) Setting the air-conditioning installation location.
(iv) Press the ON/OFF button.
Airflow range
Airflow range
Airflow range
(Left End Installation)
(Center Installation)
(Right End Installation)
(Center Installation)
L/R
L/R
(Right End Installation) (Left End Installation)
wireless
(d) Weekly timer operation
Timer operation (ON timer, OFF timer) can be set up to 4 times a day for each weekday.
(11) Silent mode
As “Silent mode start” signal is received from the wireless remote control, it operates by dropping the outdoor fan tap and the
compressor command speed.
(12) Night setback
As “Night setback” signal is received from the wireless remote control, the heating operation starts with the setting temperature
at 10
℃
.
51 rps
Outdoor fan tap
Compressor command speed
Upper limit
4th speed
Summary of Contents for SRK63ZMA-S
Page 2: ......
Page 3: ... 13 SRK T 147 TECHNICAL MANUAL ...
Page 11: ... 13 SRK T 147 2 Outdoor units Models SRC63ZMA S 71ZMA S RCR000Z008 ...
Page 12: ... 10 13 SRK T 147 Model SRC80ZMA S RCR000Z009 ...
Page 13: ... 11 13 SRK T 147 Model SRC92ZMA S RCR000Z010 ...
Page 14: ... 12 13 SRK T 147 3 Remote control a Wireless remote control Unit mm 60 26 167 ...
Page 55: ... 53 13 SRK T 147 page 42 Model SRC92ZMA S ...
Page 56: ... 54 13 SRK T 147 ...
Page 57: ... 55 13 SRK T 147 ...
Page 58: ... 56 13 SRK T 147 ...
Page 108: ... 106 13 SRK T 147 3 Super link E board SC ADNA E F ...
Page 109: ... 107 13 SRK T 147 ...
Page 110: ... 108 13 SRK T 147 ...
Page 115: ... 113 13 SRK T 147 ...
Page 121: ... 119 13 SRK T 147 ...
Page 127: ... 125 13 SRK T 147 ...
Page 133: ... 131 13 SRK T 147 ...
Page 148: ... 146 13 SRK T 147 CRBE0347 5 14 15 13 13 15 16 2 3 4 6 12 15 9 10 7 11 15 15 8 1 PANEL ASSY ...