78
-
'17 • SRK-T-206
(5) Selection of the annual cooling function
(a) The annual cooling function can be enabled or disabled by means
of the jumper wire (JA3) on the indoor unit PCB and the dip switch
(SW2-4) on the interface kit (option) PCB.
Note: (1) Default states of the jumper wire (JA3) and the interface kit at the shipping from factory –On the
PCB, the dip switch (SW2-4) is set to enable the annual cooling function.
(2) To cancel the annual cooling setting, consult your dealer.
(b) Content of control
(i)
If the outdoor air temperature sensor (TH2) detects below 5°C, the indoor fan
speed is switched to 8th step. (It is not possible to change.)
(ii)
If the outdoor air temperature sensor (TH2) detects higher than 7°C, the indoor
fan speed is changed to the normal control speed.
Jumper wire
(JA3)
Interface kit
(SC-BIKN-E)
SW2-4
Function
Shorted
ON
Enabled
Shorted
OFF
Disabled
Open
ON
Disabled
Open
OFF
Disabled
(6) High power operation
Pressing the HI POWER/ECONO button intensifies the operating power and initiates powerful cooling and heating operation for
15 minutes continuously. The wireless remote control displays and the FAN SPEED display disappears.
(a) During the HIGH POWER operation, the room temperature is not controlled. When it causes an excessive cooling and heating,
press the HI POWER/ECONO button again to cancel the HIGH POWER operation.
(b) HIGH POWER operation is not available during dehumidifying and the program timer operations.
(c) When HIGH POWER operation is set after ON TIMER operation, HIGH POWER operation will start from the set time.
(d) When the following operation are set, HIGH POWER operation will be cancelled.
①
When the HI POWER/ECONO button is pressed again.
②
When the operation mode is changed.
③
When it has been 15 minutes since HIGH POWER operation has started.
④
When the 3D AUTO botton is pressed.
⑤
When the SILENT botton is pressed.
⑥
When the NIGHT SETBACK botton is pressed.
(e) Not operable while the air-conditioner is OFF.
(f) After HIGH POWER operation, the sound of refrigerant flowing may be heard.
(7) Economy operation
Pressing the HI POWER/ECONO button initiate a soft operation with the power suppressed in order to avoid an excessive cooling or heating.
The unit operate 1.0
℃
higher than the setting temperature during cooling or 2.0
℃
lower than that during heating. The wireless
remote control displays ECONO mark and the FAN SPEED display disappears.
(a) It will go into ECONOMY operation at the next time the air-conditioner runs in the following cases.
①
When the air-conditioner is stopped by ON/OFF button during ECONOMY operation.
②
When the air-conditioner is stopped in SLEEP or OFF TIMER operation during ECONOMY operation.
③
When the operation is retrieved from CLEAN or ALLERGEN CLEAR operation.
(b) When the following operation are set, ECONOMY operation will be cancelled.
①
When the HI POWER/ECONO button is pressed again.
②
When the operation mode is changed DRY to FAN.
③
When the NIGHT SETBACK botton is pressed.
(c) Not operable while the air-conditioner is OFF.
(d) The setting temperature is adjusted according to the following table.
①
at the start of operation.
②
one hour after the start of operation.
③
two hours after the start of operation.
Temperature
adjustment
Cooling
Heating
①+0.5
①-1.0
②+1.0
②-2.0
③
③
Mode
Item
Jumper wire (JA3)
Jumper wire (J172)
ON
5
7
OFF
Outdoor air temperature ( C)
17-SRK-T206_063-092.indd 78