81
-
'17 • SRK-T-206
'09•SRK-DB-087D
(9) 3D auto operation
(a) During cooliong and heating (Including auto cooling and heating)
(i)
(ii)
Cooling
Air flow selection
Operation mode
AUTO
Heating
Indoor temp. – Setting temp. >5°C
Indoor temp. – Setting temp. 5°C
Setting temp. – Indoor temp. >5°C
Setting temp. – Indoor temp. 5°C
HIGH POWER
AUTO
HI
HI
MED
MED
ULO
ULO
LO
LO
HIGH POWER
AUTO
<
=
<
=
Flap
Louver
Cooling
Up/down swing
Heating
Wide (Fixed)
Center (Fixed)
Flap
Louver
Cooling
Heating
Left/right swing
Horizontal blowing (Fixed)
Slant forwardl blowing (Fixed)
Flap
Louver
Cooling
Up/down swing
Heating
Center (Fixed)
Wide (Fixed)
Flap
Louver
Cooling
Heating
Horizontal blowing (Fixed)
Slant forwardl blowing (Fixed)
Operation mode
Indoor temp. – Setting temp. 2°C
Setting temp. – Indoor temp. 2°C
Heating
Cooling
Air flow direction contorol
2°C < Setting temp. – Indoor temp. 5°C
2°C < Indoor temp. – Setting temp. 5°C
Indoor temp. – Setting temp. > 5°C
Setting temp. – Indoor temp. > 5°C
The control in 4) continues.
Control returns to the control in 2).
Control returns to the control in 1).
The control in 4) continues.
Control returns to the control in 2).
Control returns to the control in 1).
<
=
<
=
<
=
<
=
Wide (Fixed)
Flap
Louver
Horizontal blowing (Fixed)
1)
2)
3)
4)
5)
3
4
(b) During dehumidifying operation (including auto dehumidifying operation)
'09•SRK-DB-087D
(b) Sleep timer operation
(10)
Timer operation
(a) Comfortable timer setting (ON timer)
(c) OFF timer operation
(13)
Installation location setting
(a) Setting
(i) If the air-conditioning unit is running, press the ON/OFF button to stop.
(ii) Press the AIR FLOW U/D (UP/DOWN) button and the
AIR FLOW L/R (LEFT/RIGHT) button together for 5 seconds
or more.
(iii) Setting the air-conditioning installation location.
(iv) Press the ON/OFF button.
Airflow range
Airflow range
Airflow range
(Left end installation)
(Center installation)
(Right end installation)
(Center installation)
L/R
L/R
(Right end installation) (Left end installation)
wireless
(d) Weekly timer operation
Timer operation (ON timer, OFF timer) can be set up to 4 times a day for each weekday.
(11) Silent mode
As “Silent mode start” signal is received from the wireless remote control, it operates by dropping the outdoor fan tap and the
compressor command speed.
(12) Night setback
As “Night setback” signal is received from the wireless remote control, the heating operation starts with the setting temperature
at 10
℃
.
Outdoor fan tap (Upper limit)
Compressor command speed
48 rps
SRK63ZSPR-S
5th speed
50 rps
SRK71ZSPR-S
3rd speed
54 rps
SRK80ZSPR-S
3rd speed
17-SRK-T206_063-092.indd 81
2017/01/11 14:49:08