5
-
Item
Model
SRK71CF-BP
SRC71CF-BP
Cooling capacity
kW
7.03
Cooling power input
kW
2.12
Energy efficiency ratio
Btu/hW
11.33
Rating current
A
10.6
Cooling capacity
kW
6.3
Cooling power input
kW
2.48
Energy efficiency ratio
Btu/hW
8.67
Rating current
A
12.4
Power source
1 Phase, 220V, 60Hz
Noise level
Cooling Sound level
dB
Hi 45, Me 42, Lo 39
55
Exterior dimensions
Height
×
Width
×
Depth
mm
318
×
1098
×
248
750
×
880
×
340
Color
Yellowish white
Stucco white
Net weight
kg
15
67
Refrigerant equipment
Compressor type & Q’ty
–
2JS318H5AB02(Rotary type)
×
1
Motor
kW
–
1.5
Starting method
–
Line starting
Heat exchanger
Slit fins & inner grooved tubing
Straight fin & inner grooved tubing
Refrigerant control
Capillary tubes + Electric expansion valve
Refrigerant
(3)
kg
R22 1.75 (Pre-charged up to the piping length of 7m)
Refrigerant oil
R
0.7 (ATMOS NM56M or SUNISO 4GDID)
Deice control
Microcomputer control
Air handling equipment
Fan type & Q’ty
Tangential fan
×
1
Propeller fan
×
1
Motor
W
46
73
Air flow (at High)
(Cooling)
CMM
20.5
60
Air filter, Q’ty
Polypropylene net (washable)
×
2
–
Shock & vibration absorber
–
Cushion rubber (for compressor)
Electric heater
–
–
Operation control
Operation switch
Wireless-Remote control
–
Room temperature control
Microcomputer thermostat
–
Pilot lamp
RUN (Green), TIMER (Yellow), HI POWER (Green), ECONO (Orange)
Safety equipment
O.D
mm (in)
Liquid line:
φ
6.35 (1/4
″
)
Gas line:
φ
15.88 (5/8
″
)
Connecting method
Flare connecting
Attached length of piping
Liquid line: 0.70m
Gas line : 0.63m
–
Insulation
Necessary (Both sides)
Drain hose
Connectable
Power source supply
Terminal block (Screw fixing type)
Size
×
Core number
1.5 mm
2
×
4 cores (Including earth cable)
Connection wiring
Connecting method
Terminal block (Screw fixing type)
Accessories (included)
Mounting kit, Clean filter (Natural enzyme filter
×
1, Photocatalytic washable deodorizing filter
×
1)
Optional parts
Wired-Remote control
Notes (1) The data are measured at the following conditions.
Model SRK71CF-BP (Indoor unit)
SRC71CF-BP (Outdoor unit)
(2) The operation data are applied to the 220V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 7 m connecting piping.
(Purging is not required even in the short piping.)
If the piping length is longer, when it is 7 to 25m, add 25g refrigerant per meter.
Refrig
erant
piping
Compressor: overheat protection, Frost protection, Serial signal error protection, Indoor fan motor error
protection
(220V)
Item
Indoor air temperature
Outdoor air temperature
Standards
Operation
DB
WB
DB
WB
Cooling
27ºC
19ºC
35ºC
24ºC
ISO-T1, JIS C9612
29ºC
19ºC
46ºC
24ºC
ISO-T3, SASO 385/386
The piping length is 7.5m.
ISO-T1
(JIS)
ISO-T3
(SASO)