'15 • SR-T-185
(5)
Selection of the annual cooling function
(a)
The annual cooling control is valid from factory default setting.
It is possible to disable by cutting jumper wire (J172), or changing the setting
of dip switch (SW2-4) on the interface kit (option) PCB if it is connected.
(b) Content of control
(i) If the outdoor air temperature sensor (TH) detects below °C, the indoor
unit speed is switched to th step.
(ii) If the outdoor air temperature sensor (TH) detects higher than °C, the indoor unit speed is changed to the normal
control speed.
Jumper wire (J172)
ON
5
17
OFF
Outdoor air temperature ( C)
Pressing the HI POWER/ECONO button intensifies the operating power and initiates powerful cooling and heating operation
for 15 minutes continuously. The wireless remote control displays and the FAN SPEED display disappears.
(a) During the HIGH POWER operation, the room temperature is not controlled. When it causes an excessive cooling and heating,
press the HI POWER/ECONO button again to cancel the HIGH POWER operation.
(b) HIGH POWER operation is not available during the DRY and the program timer operations.
(c) When HIGH POWER operation is set after ON TIMER operation, HIGH POWER operation will start from the set time.
(d) When the following operation are set, HIGH POWER operation will be canceled.
①
When the HI POWER/ECONO button is pressed again.
④
When the SILENT botton is pressed.
②
When the operation mode is changed.
⑤
When the NIGHT SETBACK botton is pressed.
③
When it has been 15 minutes since HIGH POWER operation has started.
(e) Not operable while the air-conditioner is OFF.
(f) After HIGH POWER operation, the sound of refrigerant flowing may be heard.
(6) High power operation
Pressing the HI POWER/ECONO button initiate a soft operation with the power suppressed in order to avoid an excessive cooling
or heating. The unit operate 1.5
℃
higher than the setting temperature during cooling or 2.5
℃
lower than that during heating. The
wireless remote control displays ECONO mark and the FAN SPEED display disappears.
(a) It will go into ECONOMY operation at the next time the air-conditioner runs in the following cases.
①
When the air-conditioner is stopped by ON/OFF button during ECONOMY operation.
②
When the air-conditioner is stopped in SLEEP or OFF TIMER operation during ECONOMY operation.
③
When the operation is retrieved from CLEAN operation.
(b) When the following operation are set, ECONOMY operation will be canceled.
①
When the HI POWER/ECONO button is pressed again.
②
When the operation mode is changed DRY to FAN.
③
When the NIGHT SETBACK botton is pressed.
(c) Not operable while the air-conditioner is OFF.
(d) The setting temperature is adjusted according to the following table.
①
at the start of operation.
②
one hour after the start of operation.
③
two hours after the start of operation.
Temperature
adjustment
Cooling
Heating
①+
0.5
①-
1.0
②+
1.0
②-
2.0
③+1.5
③-
2.5
Mode
Item
(7) Economy operation
Jumper wire
(J
172
)
Interface kit
(SC-BIKN-E)
SW2-4
Function
Shorted
ON
Shorted
OFF
Disabled
Open
ON
Disabled
Open
OFF
Disabled
Enabled
factory default setting
#