130
-
'13 • P
A
C-T
-197
Models FDC100VSX,
125VSX,
140VSX
A
P
C
A
0
0
1
Z
5
7
1
Description
52X3
Item
Auxilliary relay
(
for CH
)
52X1
Expansion valve for heating
Current sensor
CT
SM2
Crankcase heater
CH
Fan motor
FMo1,2
THo-D
Connector
Terminal block
TB
High pressure switch
63H1
Thermistor
(
Outdoor air temp.
)
THo-A
Compressor motor
CM
Low pressure sensor
LPT
THo-P
THo-S
Expansion valve for cooling
SM1
Solenoid valve for 4 way valve
20S
Fuse
F
THo-R1,2
CnA
~
Z
SW3,5
LED1
SW1
LED2
DM
L
Diode module
Indication lamp
(
GREEN
)
Local setting switch
Pump down switch
Reactor
Auxilliary relay
(
for 20S
)
Thermistor
(
Discharger pipe temp.
)
Thermistor
(
Heat exchanger pipe temp.
)
Thermistor
(
Suction pipe temp.
)
Thermistor
(
IPM
)
Indication lamp
(
RED
)
Color
RD
Mark
Orange
OR
Yellow
/
Green
Y
/
GN
Black
BK
Blue
BL
Brown
BR
Yellow
Y
White
WH
Red
Gray
GR
Pink
P
52X6
Auxilliary relay
(
for 52C
)
+
+
Intelligent power module
IPM
Drain pan heater
DH
Relay
52C
SM1
SM2
63H1
NOISE FILTER
F
(
8A
)
F
(
4A
)
POWER SOURCE 3N
~
380
ー
415V 50Hz
TB
WH
RD
N
L1
PWB1
THo-S
THo-A
BK
BK
BK
BK
LED2
LED1
1
3
2
SW3
4
THo-R1
THo-D
RD
RD
Y
Y
SW1
3
SW5
1 2
4
t°
52X3
52X1
SW3-3,4
SW3-2
SW3-1
Local setting switch SW3
(
Set up at shipment OFF
)
Model
Power cable, indoor-outdoor connecting wires
125
15
3.5
27
φ
1.6mm x 3
φ
1.6
Model
※
At the connection with the duct type indoor unit.
125
18
23
φ
1.6mm x 3
The specifications shown in the above table are for units without heaters. For units with heaters, refer
to the installation instructions or the construction instructions of the indoor unit.
Switchgear of Circuit breaker capacity which is calculated from MAX. over current should be chosen
along the regulations in each country.
The cable specifications are based on the assumption that a metal or plastic conduit is used with no
more than three cables contained in a conduit and a voltage drop is 2%. For an installation falling
outside of these conditions, please follow the internal cabling regulations. Adapt it to the regulation
in effect in each country.
140
140
19
21
L2
L3
BK
BL
TB
BK
RD
3
1
CNEEV1
6
RD
2
4
3
1
Y OR BL
WH
(
WH
)
M
CNEEV2
(
RD
)
CNFAN1
OR
6 7
WH
5
4
1
BL BR
RD
FMo1
(
WH
)
M
BL
BL
CNS
(
RD
)
BR
BR
CNR
(
WH
)
BL
t°
t°
t°
THo-P
t°
BK
BK
52C
BL
WH
CNPS
(
WH
)
CNM
(
GR
)
BK
WH
RD
LPT
CNTH
(
WH
)
CNIP
(
Y
)
CNW
(
BK
)
CNW2
(
OR
)
CNH
(
BR
)
BK
BK
L1i
L2i
L3i
Ni
L1o
L2o
L3o
No
GN
3.5
RD
WH
BL
BK
AC1 AC2 AC3
Va
U
R1
R2
RD
RD
RD
BL
RD
BL
RD
BL
CNI 3
18V
15V
CNI1
(
WH
)
CNA1
(
WH
)
CNA2
(
WH
)
CNI2
(
WH
)
CNO1
(
RD
)
CNR
(
WH
)
GN
BK
RD
BL
RD
G
K
R5
+4
-6
P
N
CNW2
(
WH
)
CNW1
(
WH
)
BK
WH
RD
BL
R3
R4
C1
C2
WH
RD
L
RD
BL
RD
BL
RD
BK
TB5
TB6
IPM
PWB2
52C
1
3
2
4
BK
RD
BL
BK
BK
THo-R2
t°
CNB
(
RD
)
52X6
CN1
CN2-1
T12
2
Y
/
GN
POWER WIRES
SIGNAL WIRE
TO INDOOR UNIT
3
1
2
[ ]
CH
20S
RD
MS
BL
WH
CM
3
~
W
V
U
W
V
U
INVERTER
DM
CONTROL
PWB3
φ
1.6
CNFAN2
OR
6 7
WH
5
4
1
BL BR
RD
FMo2
(
WH
)
M
Optional
WH
WH
DH
CNF
(
BK
)
C4
R5
C3
Y
/
GN
52X2
100
26
16
100
CT
6
RD
2
4
3
1
Y OR BL
WH
M
52X2
Auxilliary relay
(
for DH
)
Snow guard fan control
Defrost control change
Trial operation
becomes below the freezing point.
2
1
3
4
Method of trial operation
Trial operation can be performed by using SW3-3,4.
in a very snowy country, set this switch to ON.
the compressor is not runnning when the unit is used
when outdoor temperature falls to 3
℃
or lower and
fan will run for 30 seconds in every 10 minutes,
When this switch is turned ON, the outdoor unit
turned ON in the area where outside temperature
by turning ON this switch. This switch should be
The defrosting operation interval becomes shorter
MAX over current
Power cable size
(
A
)
Power cable length
(
m
)
indoor-outdoor
wire size x number
Earth wire size
(
mm
)
MAX over current
Power cable size
(
mm
)
2
(
mm
)
2
(
A
)
Power cable length
(
m
)
indoor-outdoor
wire size x number
Earth wire size
(
mm
)
Compressor will be in the operation when SW3-3 is ON.
Cooling trial operation will be performed when SW3-4 is OFF,
and heating trial operation when SW3-4 is ON.
Be sure to turn OFF SW3-3 after the trial operation is finished.
Summary of Contents for V Multi 100VNX
Page 98: ... 97 13 PAC T 197 Models FDT100VF1 125VF 140VF H H H H H C B A F G D G PJF000Z285 A ...
Page 101: ... 100 13 PAC T 197 Models FDEN60VF 71VF1 C2 C1 A B A B D C1 C2 C1 C2 E G F C PFA003Z817 ...
Page 116: ... 115 13 PAC T 197 b Wireless remote control RCN E1R 60 17 150 Unit mm ...
Page 291: ... 290 13 PAC T 197 261 12 PAC T 173 ー K ...
Page 590: ... 589 13 PAC T 197 3 8 SUPER LINK E BOARD SC ADNA E F ...
Page 591: ... 590 13 PAC T 197 ...