Model
FDF140VSXPVD1
Indoor unit FDF71VD1 (2 units) Outdoor unit FDC140VSX
Heat Mode:HC
Cool Mode
(kW)
(kW)
Outdoor
air temp.
Indoor air temperature
18
˚C
DB
21
˚C
DB
23
˚C
DB
26
˚C
DB
27
˚C
DB
28
˚C
DB
31
˚C
DB
33
˚C
DB
12
˚C
WB
14
˚C
WB
16
˚C
WB
18
˚C
WB
19
˚C
WB
20
˚C
WB
22
˚C
WB
24
˚C
WB
˚C
DB
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
11
11.66 9.16 12.38 9.89 12.73 9.77 13.13 9.66 13.91 10.17 14.70 9.89
13
12.08 9.31 12.83 10.04 13.21 9.92 13.62 9.80 14.45 10.32 15.28 10.03
15
12.50 9.47 13.29 10.20 13.68 10.07 14.12 9.96 14.99 10.46 15.87 10.17
17
12.92 9.63 13.75 10.36 14.16 10.23 14.62 10.11 15.54 10.62 16.45 10.31
19
13.21 9.74 14.06 10.46 14.48 10.34 14.95 10.21 15.88 10.71 16.82 10.40
21
13.50 9.85 14.36 10.57 14.80 10.44 15.28 10.32 16.23 10.81 17.19 10.49
23
13.50 9.85 14.40 10.58 14.83 10.45 15.31 10.33 16.28 10.82 17.25 10.51
25
12.53 10.14 13.50 9.85 14.43 10.59 14.87 10.47 15.35 10.34 16.33 10.84 17.30 10.52
27
12.48 10.12 13.50 9.85 14.46 10.60 14.90 10.48 15.34 10.34 16.23 10.81
29
12.37 10.07 13.31 9.78 14.23 10.52 14.68 10.40 15.13 10.27 16.03 10.75
31
12.26 10.02 13.11 9.70 13.99 10.44 14.45 10.33 14.91 10.20 15.82 10.69
33
11.49 9.37 12.02 9.92 12.92 9.63 13.76 10.36 14.23 10.25 14.69 10.13 15.61 10.64
35
10.88 9.10 11.63 9.76 12.72 9.55 13.53 10.28 14.00 10.18 14.47 10.06 15.41 10.58
37
10.75 9.04 11.45 9.69 12.49 9.47 13.29 10.20 13.74 10.09 14.18 9.97 15.08 10.49
39
10.62 8.98 11.26 9.61 12.26 9.38 13.04 10.11 13.47 10.01 13.90 9.89 14.76 10.40
41
10.49 8.92 11.07 9.54 12.02 9.29 12.80 10.03 13.21 9.92 13.62 9.80 14.44 10.31
43
10.35 8.86 10.89 9.46 11.79 9.21 12.55 9.95 12.94 9.84 13.33 9.72 14.11 10.23
Outdoor
air temp.
Indoor air temperature
˚C
DB
˚C
DB
˚C
WB 16
18
20
22
24
-19.8 -20 16.13 16.00 15.87 15.74 15.61
-17.7 -18 16.19 16.07 15.94 15.81 15.68
-15.7 -16 16.26 16.13 16.00 15.87 15.74
-13.5 -14 16.26 16.13 16.00 15.87 15.74
-11.5 -12 16.25 16.13 16.00 15.87 15.74
-9.5
-10 16.25 16.13 16.00 15.87 15.74
-7.5
-8 16.25 16.12 16.00 15.87 15.74
-5.5
-6 16.25 16.13 16.00 15.87 15.74
-3.0
-4 16.25 16.13 16.00 15.87 15.73
-1.0
-2 16.25 16.13 16.00 15.86 15.73
1.0
0
16.25 16.13 16.00 15.86 15.73
2.0
1
16.26 16.13 16.00 15.86 15.73
3.0
2
16.25 16.13 16.00 15.86 15.73
5.0
4
16.25 16.13 16.00 15.86 15.73
7.0
6
16.25 16.12 16.00 15.87 15.73
9.0
8
16.93 16.80 16.68 16.54 16.40
11.5
10 17.61 17.48 17.35 17.21 17.07
13.5
12 18.53 18.39 18.25 18.12 18.17
15.5
14 19.46 19.31 19.16 19.02 19.27
16.5
16 19.93 19.77 19.61 19.48 19.82
Note(1) These data show average status.
Depending on the system control, there may be ranges where the operation is not conducted continuously.
These data show the case where the operation frequency of a compressor is fixed.(Cooling only)
(2) Capacities are based on the following conditions.
Corresponding refrigerant piping length :7.5m
Level difference of Zero.
(3) Symbols are as follows
TC :Total cooling capacity (kW)
SHC :Sensible heat capacity (kW)
HC :Heating capacity (kW)
PGA000Z770
Summary of Contents for V Multi 100VNX
Page 98: ... 97 13 PAC T 197 Models FDT100VF1 125VF 140VF H H H H H C B A F G D G PJF000Z285 A ...
Page 101: ... 100 13 PAC T 197 Models FDEN60VF 71VF1 C2 C1 A B A B D C1 C2 C1 C2 E G F C PFA003Z817 ...
Page 116: ... 115 13 PAC T 197 b Wireless remote control RCN E1R 60 17 150 Unit mm ...
Page 291: ... 290 13 PAC T 197 261 12 PAC T 173 ー K ...
Page 590: ... 589 13 PAC T 197 3 8 SUPER LINK E BOARD SC ADNA E F ...
Page 591: ... 590 13 PAC T 197 ...