461
-
WAIT
Co
m
munication error at
initial operation (1/3)
–
–
Keeps flashing 2-time flash
1. Applicable model
5. Troubleshooting
All models
Diagnosis
Countermeasure
NO
NO
NO
“ ” is still displayed on the
remote controller LED 2 minutes
after power ON.
YES
NO
Is the outdoor
unit control green LED
flashing?
YES
Is the outdoor unit
control red LED flashing
twice?
Are wires
connected properly between indoor/
outdoor units?
YES
YES
YES
YES
NO
Is approx.
DC20V detected between
�
-
�
on
the outdoor unit terminal
block?
Is approx.
DC20V detected between
�
-
�
on
the indoor unit terminal
block?
WA IT
To next page
Defective indoor control PCB
➞
Replace.
Defective remote control
➞
Replace.
Broken remote control wire Y
➞
Replace.
Correct connection wires
between indoor and
outdoor units.
Defective outdoor control
PCB
➞
Replace.
Defective connection wire
(Broken)
Noise
Defective indoor control
PCB
➞
Replace.
2. Error detection method
3.
Condition of Error displayed
4. Presumable cause
• Faulty indoor control PCB
• Defective remote control
• Broken remote control wire
• Faulty outdoor control PCB
• Broken connection wires
Note:
Error code
Remote control:
Indoor
display
RUN light TIMER light
Green LED Red LED
Outdoor
control PCB
Content
-
461
-
'13 • PAC-T-197
Summary of Contents for V Multi 100VNX
Page 98: ... 97 13 PAC T 197 Models FDT100VF1 125VF 140VF H H H H H C B A F G D G PJF000Z285 A ...
Page 101: ... 100 13 PAC T 197 Models FDEN60VF 71VF1 C2 C1 A B A B D C1 C2 C1 C2 E G F C PFA003Z817 ...
Page 116: ... 115 13 PAC T 197 b Wireless remote control RCN E1R 60 17 150 Unit mm ...
Page 291: ... 290 13 PAC T 197 261 12 PAC T 173 ー K ...
Page 590: ... 589 13 PAC T 197 3 8 SUPER LINK E BOARD SC ADNA E F ...
Page 591: ... 590 13 PAC T 197 ...