14 - 68
MELSEC-A
14 TROUBLESHOOTING
Division of
warning
Warning
code
Warning name
Description
Action at occurrence of warning
500
Deceleration and
stop speed
change
A speed change request is issued during
deceleration and stop.
Speed change is not carried out.
501
Speed limit value
over
The new speed value given during operation
exceeds the speed limit value.
•
The speed is controlled to the “speed limit
value.”
•
The “in speed limit flag” is turned ON.
503
M code ON
signal ON start
The M code ON signal is turned ON during
execution of positioning data.
Execution of positioning data continues.
505
No operation end
setting
In the block start positioning operation, the
setting at 50th point in the positioning start
data indicates continuation.
Operation is terminated.
506
FOR to NEXT
nesting structure
There is a nested set of FOR and NEXT.
508
Speed/position
changeover
signal ON during
acceleration
The changeover signal is turned ON during
acceleration under speed/position changeover
control.
Operation continues.
509
Insufficient
remaining
distance
The deceleration distance for a speed change
request is insufficient.
A speed change occurs at the nearest value.
(However, the request is ignored if the
operation pattern is continuous path control.)
“2: Restart” is specified for the step start
information in the “in step wait” axis operation
status.
511
Invalid step start
information
"1: Step continue" or "2: Restart" is set to the
step start information in the axis operation
status of "step error occurring", "error
occurring", "waiting", "stopped", "servo has not
been connected" or "in servo OFF".
Step operation does not start.
512
Illegal external
start function
The “external start function selection” setting in
detail parameter 2 exceeds the setting range.
Nothing occurs in response to the external start
signal.
513
Insufficient
movement
amount
There is no movement amount necessary for
automatic deceleration.
Immediate stop after the positioning address is
reached
Positioning
operation
514
Outside
command speed
range
The command speed exceeds the speed limit
value.
•
The command speed is controlled to the
“speed limit value.”
•
The “in speed limit flag” is set.
Summary of Contents for A1SD75M1
Page 2: ......
Page 20: ...A 18 MEMO...
Page 22: ...MEMO...
Page 27: ...1 5 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 42: ...1 20 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 52: ...2 10 MELSEC A 2 SYSTEM CONFIGURATION MEMO...
Page 111: ...5 21 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 115: ...5 25 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 123: ...5 33 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 127: ...5 37 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 167: ...5 77 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 193: ...5 103 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 276: ...5 186 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 332: ...7 18 MELSEC A 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Page 334: ...MEMO...
Page 422: ...9 64 MELSEC A 9 MAIN POSITIONING CONTROL MEMO...
Page 446: ...10 24 MELSEC A 10 ADVANCED POSITIONING CONTROL MEMO...
Page 472: ...11 26 MELSEC A 11 MANUAL CONTROL MEMO...
Page 576: ...12 104 MELSEC A 12 CONTROL AUXILIARY FUNCTIONS MEMO...
Page 745: ......