background image

 

AJ65BT-64AD

 

Analog-Digital Converter Module 

 

MITSUBISHI

 

General-Purpose PROGRAMMABLE CONTROLLER

 

User's Manual

 

(Hardware)

 

Thank you for buying the Mitsubishi general-purpose 
programmable controller MELSEC-A Series.

 

Prior to use, please read both this manual and detailed 
manual thoroughly and familiarize yourself with the product.

 

 

 
 

MODEL AJ65BT-64AD-U-H-E 

MODEL  

CODE 

13J892 

IB (NA) 66748-G (0810) MEE 

 
 

©1996 MITSUBISHI ELECTRIC CORPORATION 

 
 
 
 
 
 
 

SAFETY PRECAUTIONS        

(Read these precautions before using this product.) 

Before using this product, please read this manual and the relevant manuals carefully 
and pay full attention to safety to handle the product correctly. 
These precautions apply only to Mitsubishi equipment. Refer to the CPU module user’s 
manual for a description of the programmable controller system safety precautions. 
In this manual, the safety precautions are classified into two levels: "DANGER" and 
"CAUTION". 

DANGER 

Indicates that incorrect handling may cause hazardous 
conditions, resulting in death or severe injury. 

CAUTION 

Indicates that incorrect handling may cause hazardous 
conditions, resulting in minor or moderate injury or property 
damage. 

Under some circumstances, failure to observe the precautions given under "
CAUTION" may lead to serious consequences. 
Observe the precautions of both levels because they are important for personal and 
system safety. 
Make sure that the end users read this manual and then keep the manual in a safe place 
for future reference. 
 

[Design Precautions] 

DANGER 

• 

In the case of a communication failure in the network, data in the master 
module are held. 
Check the communication status information (SB, SW) and configure an 
interlock circuit in the sequence program to ensure that the entire system 
will operate safely. 

 

CAUTION 

• 

Do not install the control lines or communication cables together with the 
main circuit lines or power cables. 
Keep a distance of 100mm (3.94 inches) or more between them. 
Failure to do so may result in malfunction due to noise. 

 

[Installation Precautions] 

CAUTION 

• 

Use the programmable controller in an environment that meets the 
general specifications in this manual. 
Failure to do so may result in electric shock, fire, malfunction, or damage 
to or deterioration of the product. 

• 

For protection of the switches, do not remove the cushioning material 
before installation. 

• 

Do not directly touch any conductive part of the module. 
Doing so can cause malfunction or failure of the module. 

• 

Securely fix the module with a DIN rail or mounting screws. Tighten the 
screws within the specified torque range. 
Undertightening can cause drop of the screw, short circuit or malfunction. 
Overtightening can damage the screw and/or module, resulting in drop, 
short circuit, or malfunction. 

 
[Wiring Precautions] 

CAUTION 

• 

Shut off the external power supply for the system in all phases before 
wiring. Failure to do so may result in damage to the product. 

• 

Ground the FG terminals to the protective ground conductor dedicated to 
the programmable controller. 
Failure to do so may result in malfunction. 

• 

Check the rated voltage and terminal layout before wiring to the module, 
and connect the cables correctly. 
Connecting a power supply with a different voltage rating or incorrect 
wiring may cause a fire or failure. 

• 

Use applicable solderless terminals and tighten them within the specified 
torque range. 
If any spade solderless terminal is used, it may be disconnected when the 
terminal screw comes loose, resulting in failure. 

• 

Tighten the terminal screw within the specified torque range. 
Undertightening can cause short circuit or malfunction. 
Overtightening can damage the screw and/or module, resulting in drop, 
short circuit, or malfunction. 

• 

Prevent foreign matter such as dust or wire chips from entering the 
module. Such foreign matter can cause a fire, failure, or malfunction. 

• 

Do not install the control lines or communication cables together with the 
main circuit lines or power cables. Failure to do so may result in 
malfunction due to noise. 

• 

Place the cables in a duct or clamp them. 
If not, dangling cable may swing or inadvertently be pulled, resulting in 
damage to the module or cables or malfunction due to poor contact. 

• 

When disconnecting the cable from the module, do not pull the cable by 
the cable part. Loosen the screws of connector before disconnecting the 
cable. Failure to do so may result in damage to the module or cable or 
malfunction due to poor contact. 

 

[Startup and Maintenance Precautions] 

CAUTION 

• 

Do not touch the terminals before shutting off the external power supply for 
the system in all phases.  
Doing so may cause malfunction. 

• 

Do not change the setting jumper before shutting off the external power 
supply for the system in all phases. 
Doing so may cause failure or malfunction. 

• 

Shut off the external power supply for the system in all phases before 
cleaning the module or retightening the terminal screws. 
Failure to do so may cause the module to fail or malfunction. 

• 

Do not disassemble or modify the modules. 
Doing so may cause failure, malfunction, injury, or a fire. 

• 

Do not drop or apply strong shock to the module.  
Doing so may damage the module. 

• 

Shut off the external power supply for the system in all phases before 
mounting or removing the module to or from the panel. 
Failure to do so may cause the module to fail or malfunction. 

• 

After the first use of the product, do not mount/remove the terminal block 
to/from the module more than 50 times (IEC 61131-2 compliant). 

• 

Before handling the module, touch a grounded metal object to discharge 
the static electricity from the human body. 
Failure to do so may cause the module to fail or malfunction. 

 
[Disposal Precautions] 

CAUTION 

• 

When disposing of this product, treat  it as industrial waste. 

 

About Manuals 

The following manuals are also related to this product.  
In necessary, order them by quoting the details in the tables below. 

 

Detailed Manual 

 

Manual Name 

Manual No. 

(Type code) 

AJ65BT-64AD Analog-Digital Converter Module User's 
Manual 

SH-3614 
(13J893) 

 

Related Manuals 

 

Manual Name 

Manual No. 

(Type code) 

CC-Link System Master/Local Module User's Manual type 
AJ61BT11/A1SJ61BT11 

IB-66721 
(13J872) 

CC-Link System Master/Local Module User's Manual type 
AJ61QBT11/A1SJ61QBT11 

IB-66722 
(13J873) 

CC-Link System Master/Local Module User's Manual type 
QJ61BT11N 

SH-080394E 

(13JR64) 

 

Compliance with the EMC and Low Voltage Directives 

(1) For programmable controller system 

To configure a system meeting the requirements of the EMC and Low 
Voltage Directives when incorporating the Mitsubishi programmable controller 
(EMC and Low Voltage Directives compliant) into other machinery or 
equipment, refer to the "EMC AND LOW VOLTAGE DIRECTIVES" chapter 
of the User's Manual for the CPU module used. 
The CE mark, indicating compliance with the EMC and Low Voltage 
Directives, is printed on the rating plate of the programmable controller. 

(2) For the product 

For the compliance of this product with the EMC and Low Voltage Directives, 
refer to the "CC-Link module" section in the "EMC AND LOW VOLTAGE 
DIRECTIVES" chapter of the User's Manual for the CPU module used. 

 

1. Overview 

This user's manual describes the specification, name of each part and wiring for 
the AJ65BT-64AD analog-digital converter module (abbreviated as AJ65BT-
64AD from here on), used as a CC-Link system remote device station. 
 
After unpacking, confirm if the following item is included. 

Item name 

Numbers of item 

AJ65BT-64AD main module 

 

2. Performance 

Specifications 

2.1 Performance 

Specifications 

The AJ65BT-64AD performance specification is described below. 
Refer to CPU module User's Manual to be used for general specification of 
AJ65BT-64AD. 
 

Item Specification 

Analog input 

Voltage: -10 to 0 to +10V DC (input resistance 1M

Ω

Current: -20 to 0 to +20mA DC (input resistance 250

Ω

Selected by the 
input terminal 

Digital output 

16-bit encoded binary (data area 12bits) 

I/O characteristics *1 

Analog input value 

Digital output value 

 

-10 to 10V or -20 to 20mA 

0 to 10V or 0 to 20mA 

0 to 5V or 0 to 20mA 
1 to 5V or 4 to 20mA 

0 to 4000 or -2000 to 2000 
0 to 4000 or -2000 to 2000 
0 to 4000 or -2000 to 2000 
0 to 4000 or -2000 to 2000 

Maximum 
resolution 

-10 to 10V or -20 to 20mA 

0 to 10V or 0 to 20mA 

0 to 5V or 0 to 20mA 
1 to 5V or 4 to 20mA 

5mV or 20

μ

2.5mV or 10

μ

1.25mV or 5

μ

1mV or 4

μ

Total precision *2 

±

1% (

±

40) 

Maximum 
conversion speed 

1 ms/channel 

Absolute 
maximum input 

Voltage 

±

15 V, current 

±

30 mA

*3

 

Analog input 
points 

4channels/module 

Insulation method  Photo-coupler insulation between power supply/communication and analog 

input (not insulated between channels) 

CC-Link station 
type 

Remote device station 

Number of 
occupied stations 

2 stations 

Connection 
terminal 

27-point terminal block 

External power 
supply 

24VDC (18 to 30VDC) 

Supported cable 
size 

0.75 to 2.00mm

2

 

Module mounting 
screws 

M4 x 0.7 mm x 16mm or more (M4 x 0.028 inch x 0.63 inch) 

Can be installed with DIN rail. 

Supported DIN rail 

TH35-7.5Fe, TH35-7.5Al, TH35-15Fe (conforming to JIS C 2812) 

Supported 
solderless terminal 

RAV 1.25-3.5, RAV 2-3.5 

Internal 
consumption 
current 

0.12 A (at 24VDC) 

Noise durability 

By a noise simulator with the following specification:  

Noise voltage at 500Vp-p, Noise width at 1

μ

s, Noise frequency at 25 to 

60Hz 

Dielectric 
withstand voltage 

Between power supply/communication system batch and analog input 

batch:500VAC, 1minute 

Insulation resistor 

Between power supply/communication system batch and analog input 

batch:500VDC, more than 10M

Ω

 on insulation resistance tester. 

Weight 0.35 

(0.77) 

kg(lb.) 

*

1

 

Gain is set to 10V/20mA and the offset is set to 0V/4mA (setting pin A) at the time of 

factory shipment. 

However, when using for current, change the set pin B, and the RYn1 (voltage/current 

selection) must be turned on. 

*2 This is the accuracy in respect to the maximum digital output value (+4000). 

The same value (+4000) applies for the current input and voltage input. 

*3 Current value indicates value of instant input current that does not break module inner 

electrical resistance. 

 

 

Point  

The range for the analog input for conversion is as follows: 

Voltage : -10 to 0 to +10V 
Current : -20 to 0 to +20mA 

 

 