32
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
<RECORD SETTINGS>
■
Settings concerning normal recording and
alarm recording
This unit allows independent settings for normal recording
and alarm recording. By this, more detailed settings are
possible such as changing the recording intervals of the
camera inputting the alarm signals while maintaining the
normal recoding settings as they are.
!
During recording, the setting in the <RECORD
SETTING> screen cannot be changed.
!
When setting a camera number not connected
with a camera in RECORD SETTING, warning dis-
play of “NON SIGNAL” appears (for details, see Warn-
ings and CALL OUT output”,
see page 87 ).
■
Recording mode settings for normal
recording and alarm recording
The recording intervals and recording picture quality for
normal recording and the recording intervals, recording
picture quality and whether to perform pre-alarm record-
ing for alarm recording can be set here (for normal record-
ing, see “Basic manual recording”,
see pages 12-14).
Pre-alarm recording is a function to start recording a few
seconds before the ALARM IN terminal on the rear of the
unit is grounded or motion is detected during alarm re-
cording (for details concerning pre-alarm recording,
see page 48).
<RECORD SETTINGS>
>>RECORD SETTING
ALARM REC DURATION 5S
PRE ALARM REC OFF
1. Press the SET UP button
}
<SETTINGS>
}
Select
“RECORD SETTING” in the <RECORD SETTINGS> screen
and turn the SHUTTLE ring clockwise.
• The <RECORD SETTING> screen appears.
2. Turn the JOG dial and move the cursor to camera selection
item for alarm recoding and turn the SHUTTLE ring clockwise.
• The background setting turns red and flashes.
9
7
4
5
6
1
2
3
8
CAUTION : For <ESTD TIME>,
see “Continuous recording time table” , page 82.
<RECORD SETTING> ALARM PLUS
NO.PPS GRADE A-PPS A-GRADE
>> 1.39P STD 1.39P STD
1.39P STD 1.39P STD
1.39P STD 1.39P STD
1.39P STD 1.39P STD
1.39P STD 1.39P STD
1.39P STD 1.39P STD
1.39P STD 1.39P STD
1.39P STD 1.39P STD
1.39P STD 1.39P STD
<ESTD TIME> H M
Camera selection during alarm recording
• Setting ( default : “ALARM PLUS ” )
“ALL” : Alarm recording is performed for all cameras set for
alarm recording.
“ALARM” : Alarm recording is performed for only the
cameras set for alarm recording and inputted with alarm
signals. When there is input of alarm signals from multiple
cameras, alarm recording is performed for all cameras
containing alarm signals.
“ALARM PLUS” : Recording is performed in the frame speed
set in “A-PPS” for the camera inputted with alarm signals
during normal recording. All other cameras will be recording
in the normal frame intervals.
3. Display the desired item to set and turn the SHUTTLE ring
clockwise.
• The setting is confirmed and flashing stops.
4. (When setting the recording intervals and recording picture
quality for normal recording • • •)
Turn the JOG dial to select the desired camera number and
turn the SHUTTLE ring clockwise twice.
• The “PPS” setting display reverses in color when the
SHUTTLE ring is turned the first time. When the ring is turned
for the second time, the background turns red and flashes.
• Setting ( default : “15P” )
“25P”, “12.5P”, “8.33P”, “6.25P”, “5P”, “4.17P”, “3.13P”,
“2.5P”, “1P”, “0.5P”, “0.25P”, “0.13P”, “- - - - -”
“- - - - -” : Recording cannot be performed with camera set to
this item.
For details concerning normal recording settings,
see “Setting the recording intervals and recording
picture quality for normal recording”,
see pages
12-14.
5. Display the desired item to set and turn the SHUTTLE ring
clockwise.
• The setting is confirmed and flashing stops.
6. Turn the JOG dial clockwise to reverse display the “GRADE”
setting and turn the SHUTTLE ring clockwise.
• The background of the “PPS” display changes to red and
flashes.
• Setting ( default : “STD” )
“SUPER”, “HIGH”, “STD”(STANDARD), “BASIC”, “LONG”
7. Display the desired item to set and turn the SHUTTLE ring
clockwise.
• The setting is confirmed and flashing stops.
8. (When setting recording intervals and recording picture
quality for alarm recording • • • )
Repeat steps 4 ~ 7 and select desired settings for “A-PPS”
and “A-GRADE” as well.
9. When completed with settings, turn the SHUTTLE ring
counterclockwise.
• The cursor moves to the camera number directly to the
left.
10. When continuing with other camera number, turn the JOG
dial to move the cursor to the desired camera number and
repeat steps 4 ~ 9 for settings.
11. When completed with all settings, turn the SHUTTLE ring
counterclockwise or press the SET UP button.