42
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
<INITIAL SET UP/INFORMATION> (continued)
4. Display the desired sub item and turn the SHUTTLE ring
clockwise.
• The setting is confirmed and flashing stops.
5. To make additional changes, repeat steps 3 and 4.
6. Turn the SHUTTLE ring counterclockwise or press the SET
UP button.
■
INFORMATION/SERVICE
In the <INFORMATION/SERVICE> screen, the log list/de-
vice list during power failures, etc., can be checked and
the menus can be reset. At the bottom of the menu screen,
the accumulated operation time since the beginning of us-
age is displayed.
♦
HDD/CFC INFORMATION
The recorded range of the HDD or Compact Flash Card
inserted in the unit can be checked.
1. (To check the recorded range of the HDD • • • )
Press the SET UP button
}
<SETTINGS>
}
<INITIAL SET
UP/INFORMATION>
}
Select “HDD INFORMATION” in the
<INFORMATION/SERVICE> screen. Display the desired
setting and confirm.
• The <INFORMATION> screen appears.
<INFORMATION>
HDD
MASTER HDD(80GB)
SLAVE NONE
START 02-02-2002 00:00:00
END 04-04-2002 12:30:15
2. (To check the recorded range of the Compact Flash inserted
in the unit or to check the menu information recording status •
• • )
Select the SET UP button
}
<SETTINGS>
}
<INITIAL SET
UP/INFORMATION>
}
Select “CFC INFORMATION” in the
<INFORMATION/SERVICE> screen and turn the SHUTTLE
ring clockwise.
• The <INFORMATION> screen of the Compact Flash inserted
in the unit is displayed.
<INFORMATION>
CFC
CAPACITY 64MB
MENU INFORMATION
START 02-02-2002 00:00:00
END 02-02-2002 00:00:10
3. Turn the SHUTTLE ring counterclockwise or press the SET
UP button.
♦
WARNING LOG LIST
The WARNING LOG LIST enables to check the number of
failure, date, time and type of failure during power failures,
etc.
<INFORMATION/SERVICE>
HDD INFORMATION
CFC INFORMATION
>>WARNING LOG LIST
SETTING DATA INITIALIZE
HDD DATA CLEAR
CFC DATA CLEAR
ELAPSED TIME 10H
1. Press the SET UP button
}
<SETTINGS>
}
<INITIAL SET
UP/INFORMATION>
}
Select “WARNING LOG LIST” in the
<REAR TERMONAL SETTINGS> screen. Display the desired
setting and confirm.
• The <WARNING LOG LIST> screen appears.
• The WARNING LOG LIST can display up to 1000 items. When
the number of items exceed this limit, the latest 1000 items
are displayed.
•
button/turn JOG dial counterclockwise : Selection moves
to the next number.
•
button/turn JOG dial clockwise : Selection moves to the
previous number.
• button : Displays the page with date prior to the date of
the currently opened page.
• button : Displays the page with date newer than the date
of the currently opened page.
• To reset the WARNING LOG LIST, press the WARNING
RESET button for 5 seconds.
When a failure occurs while the <WARNING LOG
LIST> is being displayed, exit the screen and dis-
play the screen again. A new item will be added to
the list.
Failures displayed in the WARNING LOG LIST (
see page 87).
<WARNING LOG LIST>
NO DATE TIME WARNING
>>0001 02-02-02 10:00:00 ALM ON
“P-LOSS” : Power failure.
“SYS RST” : Reset button was pressed and the unit
was reset.
“HLD ON” : ALARM HOLD button was pressed and
the unit was put on hold.
“HLD OFF” : ALARM HOLD button was pressed and
the alarm hold was canceled.
2. Turn the SHUTTLE ring counterclockwise or press the SET
UP button.
♦
SETTING DATA INITIALIZE
Menu screen settings is reset.
1. Press the SET UP button
}
<SETTINGS>
}
<INITIAL SET
UP/INFORMATION>
}
Select “SETTING DATA INITIALIZE”
in the <INFORMATION/SERVICE> screen. Display the
desired setting and confirm.
• The <SETTING DATA INITIALIZE> screen appears.
• When not resetting menu screen settings, turn the SHUTTLE
ring counterclockwise.
<SETTING DATA INITIALIZE>
>>EXECUTE
SHUTTLE>>:EXECUTE,<<:CANCEL