89
ENGLISH
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Specifications
Specifications
Rated Power Supply:
AC 100-240V 50/60Hz
Rated Input:
1.0 - 0.5A (100-240V)
Color System:
PAL-type color system.
Operating Temperature:
41
°
F-104
°
F (5
°
C to 40
°
C).
Relative Humidity:
Max.80(%)
Altitude:
Max.2000(m)
Dimensions:
300(Width) x 350(Depth) x 88(Height)(mm).
Weight:
5.0kg
Recording System
Digital recording method using WAVELET compression.
Sampling
13.5MHz
Data Compression
WAVELET
Compression Unit
Field
Resolution
684 x 244
Recording Device
80GB HDD
Video Input:
9 Input BNC-Connector:
1.0 V(p-p), 75 ohms.
Monitor Output:
S-Connector:
Y-Signal: 1.0 V(p-p), 75 ohms.
C-Signal: 0.286 V(p-p), 75 ohms.
BNC-Connector:
1.0 V(p-p), 75 ohms.
Throughout Output:
9 Output BNC-Connector:
1.0 V(p-p), 75 ohms.
Audio Input:
-8 dBs, 50 kohms.
Audio Output:
-8 dBs, 1 kohms.
Microphone Input:
-67 dBs, 600 ohms.
Timer Program:
8programs-Daily start and stop time for one week x 3set.
Memory Backup:
Lasts for more than 1 month.
CONNECTORS
ALARM IN(1-9) Input:
Terminal for starting alarm recording.
CLOCK ADJ Input:
Terminal for adjusting clock.
REC Input:
Terminal for start recording.
EMERGENCY Input:
Terminal for start emergency recording.
GND:
Terminal for ground.
MODE OUT(1-4) Output:
Terminal for indication of recording selected mode.
DC 5V OUT Output:
Terminal for DC 5V OUT.
CALL OUT/CALL OUT GND:
Terminal for external warning device.
Rating:
MODE OUT(1-4)
Active:
“Low” Level.
Max. Drive current 7mA DC.
Non active:
Open.
Max. V24V DC.
ALARM IN / CLOCK ADJ /
Active:
When terminals are short-circuited
REC/EMERGENCY
or “Low” Level voltage is applied.
Non active:
Open.
CALL OUT /
Active:
ON.
Max. Drive current 7mA DC.
CALL OUT GND
Non active:
Open.
Max. V24V DC.
RS-232C
RS-232C (D-SUB 9pin) terminal for connection with personal computer.
Accessories
AC power cord (for U.K / for the Continent)
2
Compact Flash cover (mounted on unit)
1
Compact Flash Card recording format
Original format (FSM1)
Weight and dimensions shown are approximate.
Design and specifications are subject to change without notice.
<Interface circuit inside the unit>
5V
5V
10k
Ω
22k
Ω
Input
terminal
0.047
µ
F
GND
EMERGENCY/ALARM IN/REC/
CLOCK ADJ Input terminal
• Input Circuit
<Interface circuit inside the unit>
Output terminal
GND terminal
MODE OUT 1 - 4 Output terminal
• Output Circuit
<Interface circuit inside the unit>
CALL OUT terminal
CALL OUT GND terminal
CALL OUT output terminal
• Output Circuit