Graphic Operation Terminal F940GOT
Introduction 1
1-21
•
Communication setting
The setting related to communication can be performed using the screen creation software
or the GOT main body. (As to the screen creation software, refer to the operation manual of
the software.)
To use general-purpose communication, select "SET-UP MODE", "PLC TYPE" and "UNI-
VERSAL" in this order in the GOT main body.
To set the baud rate, the data length, the stop bit length and the parity, select "SET-UP
MODE" and "SERIAL PORT (RS-232C)" in this order in the GOT main body.
Set each parameter to an either value shown below.
Baud rate
19,200 / 9,600 / 4,800 / 2,400 / 1,200 / 600 or 300 bps
Data length
8 or 7 bits
Stop bit length
1 or 2 bits
Parity
Even, odd or none