I/O SIGNAL LIST
6.1 CC-Link Extended Setting (Pr. 544)
Remote register function can be extended.
*1
The program used for conventional series inverter (FR-A5NC) can be used.
When RYD, RYE, and RYF turn on simultaneously, only one of them is executed.
The upper 8 bits of RWw2 are link parameter expansion setting.
*2
When using double, quadruple and octuple settings of the CC-Link Ver.2, station data of the master station must
be set to double, quadruple and octuple also.
(If the master station is CC-Link Ver.1 compatible station, the above setting can not be made.)
*3
Pr.544 CC-Link extended setting
= "100, 112, 114, 118" are available with the FR-A700 series-NA/EC version inverter only.
Parameter
Number
Name
Initial
Value
Setting
Range
Description
Refer
to page
CC-Link Ver.
544
CC-Link extended
setting
0
0
1
Occupies one station
(FR-A5NC compatible)
1
Occupies one station
2
Occupies one station double
Occupies one station quadrople
Occupies one station octuple
100
1
Occupies one station
(PLC function)
112
2
Occupies one station double
(PLC function)
114
Occupies one station quadrople
(PLC function)
118
Occupies one station octuple
(PLC function)
REMARKS
The setting change is reflected after an inverter reset. (Refer to
page 35
for inverter reset.)