background image

12

外形寸法図

●FR-HEL-H220K〜H280K

単位 (mm)

●FR-HEL-H315K、H355K

単位 (mm)

E

P1

P

P1

P

W1

W±2

MAX D

H1

H±10

(Sネジ用)

4−取付け穴

(S1ネジ用)

接地端子

2−S2吊りナット

(φボルト用)

* 吊りナットは製品取付け後、取り外してください。

2−端子

形 名

モータ容量

W

W1

H

H1

D

S

S1

S2

φ

質量

(kg)

FR-HEL-H220K

220K

175

150 405 370 240 M8

M6

M6 M12

30

FR-HEL-H250K

250K

190 165 440 400 250 M8

M8

M8 M12

35

FR-HEL-H280K

280K

190 165 440 400 255 M8

M8

M8 M16

38

E

P1

P

P1

P

185

210±2

MAX250

450

495±10

(M10ネジ用)

4−取付け穴

(M8ネジ用)

接地端子

2−M8吊りナット

(M16ボルト用)

* 吊りナットは製品取付け後、取り外してください

2−端子

形 名

モータ容量 質量(kg)

FR-HEL-H315K

315K

42

FR-HEL-H355K

355K

46

Summary of Contents for FR-HEL Series

Page 1: ...INVERTER Instruction Manual JAPANESE ENGLISH FR HEL 0 4K 110K FR HEL H0 4K H355K DC DC REACTOR...

Page 2: ...A 1 JAPANESE 3...

Page 3: ...A 2 4 1 2 3 4 5 1 10 50 90 RH 20 65 1 1000m 5 9m s2 10 55Hz X Y Z...

Page 4: ...1 JAPANESE 1 2 2 2 3 3 4 4 5 6 6 7...

Page 5: ...2 1 1 2 2 1 6 2 10 50 10cm 5cm DC FR HEL 1 1 200V 15K 400V 55K 1 DC REACTOR FR HEL K FR HEL H K XXXXXXXXXXX SERIAL MITSUBISHI ELECTRIC CORP MODEL kW 200V MITSUBISHI H 400V 10cm 5cm 5cm 5cm 5cm...

Page 6: ...3 JAPANESE 3 1 P P1 P P1 5m 4 P1 P 200V 18 5K 400V 75K 2 0 4kW 0 4kW 3 55K 4 7 75K 1 2 3 4 P1 P N OFF P N DC50V 5 200V 18 5K 400V 75K 3 NFB R L1 S L2 T L3 U V W P1 P1 P MC M P N FR HEL P1 P 5m...

Page 7: ...5 4 5 5 FR HEL 11K M6 3 8 14 6 14 8 6 8 FR HEL 15K M6 3 8 22 6 22 14 6 14 FR HEL 18 5K M8 13 2 38 8 38 14 6 14 FR HEL 22K M10 26 5 38 10 38 22 6 22 FR HEL 30K M10 26 5 60 10 60 22 6 22 FR HEL 37K M10...

Page 8: ...EL H37K M8 7 8 22 8 22 14 5 14 FR HEL H45K M8 7 8 38 8 38 22 5 22 FR HEL H55K M8 7 8 60 8 60 22 6 22 FR HEL H75K M12 46 1 60 12 60 22 6 22 FR HEL H90K M12 46 1 80 12 80 22 6 22 FR HEL H110K M12 46 1 8...

Page 9: ...6 5 1 JEM TR201 100 25 1 94 4 0 4kW 93 94 4 100 200V 3 AC 200 240V 50Hz 60Hz 400V 55K 3 AC 380 480V 50Hz 60Hz 75K 3 AC 380 500V 50Hz 60Hz 10 50 90 20 65 1000 5 9 s2...

Page 10: ...5 74 81 61 21 0 5 FR HEL 1 5K 1 5K 85 74 81 70 30 0 8 FR HEL 2 2K 2 2K 85 74 81 70 30 0 9 P1 P W 2 W1 D2 MAX D d 1 D3 H 2 D1 2 W W1 H D 2 D1 D2 D3 d kg FR HEL 3 7K 3 7K 77 55 92 82 66 57 37 M4 1 5 FR...

Page 11: ...3 175 117 104 115 5 6 FR HEL 30K 30K 114 72 100 200 125 101 135 7 8 FR HEL 37K 37K 133 86 117 195 115 98 135 10 FR HEL 45K 45K 133 86 117 205 125 108 140 11 FR HEL 55K 55K 153 126 132 209 135 122 140...

Page 12: ...5K H2 2K mm 4 2 M5 Max78 90 2 5 75 Max 60 28 P P1 kg M3 5 0 6 D3 H 2 5 Max D 4 M4 D2 W 2 5 50 D1 1 P P1 W H D D1 D2 D3 kg FR HEL H0 75K 0 75K 66 100 70 68 48 34 0 8 FR HEL H1 5K 1 5K 66 100 80 74 54 3...

Page 13: ...5 D3 H 2 5 Max D 4 d D2 W 2 5 W1 D1 1 P P1 W W1 H D D1 D2 D3 d kg FR HEL H11K 11K 105 75 137 110 105 85 53 M5 4 5 FR HEL H15K 15K 105 75 152 125 115 95 62 M5 5 FR HEL H18 5K 18 5K 114 75 162 120 100...

Page 14: ...R HEL H75K 75K 140 120 320 295 185 16 FR HEL H90K 90K 150 130 340 310 190 20 E P1 P P1 P W1 W 2 MAX D H1 H 10 S M6 M12 W W1 H H1 D S kg FR HEL H110K 110K 150 130 340 310 195 M6 22 FR HEL H132K 132K 17...

Page 15: ...2 W W1 H H1 D S S1 S2 kg FR HEL H220K 220K 175 150 405 370 240 M8 M6 M6 M12 30 FR HEL H250K 250K 190 165 440 400 250 M8 M8 M8 M12 35 FR HEL H280K 280K 190 165 440 400 255 M8 M8 M8 M16 38 E P1 P P1 P 1...

Page 16: ...conditions Please follow the instructions of both levels because they are important to personnel safety WARNING CAUTION CAUTION SAFETY INSTRUCTIONS WARNING While power is on or when the option is run...

Page 17: ...ten included in fumigant which is used to sterilize or disinfest wooden packages When packaging prevent residual fumigant components from being infiltrated into Mitsubishi products or use an alternati...

Page 18: ...1 ENGLISH Contents 1 Product Checking 2 2 Installation 2 3 Wiring 3 4 Cable Size and Crimping Terminal 4 5 Specifications 6 6 Outline Dimension Drawings 7...

Page 19: ...t to make the surrounding air temperature higher than the permissible value 10 C to 50 C In addition as the reactor itself generates heat leave sufficient clearance around it Independent of the instal...

Page 20: ...cable When you are using an earthing grounding cable wire the cable to the installation hole where varnish is removed Refer to page 4 for the cable and solderless terminal sizes and page 7 for the po...

Page 21: ...inal HIV Cable Size mm2 Crimp ing Ter minal Cable Size mm2 FR HEL 0 4K to 2 2K M4 1 5 2 4 2 2 4 2 FR HEL 3 7K M4 1 5 5 5 4 3 5 5 5 4 3 5 FR HEL 5 5K M4 1 5 5 5 4 5 5 5 5 4 5 5 FR HEL 7 5K M5 2 5 14 5...

Page 22: ...5 5 5 5 5 5 5 5 FR HEL H15K M6 4 4 8 6 8 5 5 5 5 5 FR HEL H18 5K M6 4 4 14 6 14 8 5 8 FR HEL H22K H30K M6 4 4 22 6 22 14 5 14 FR HEL H37K M8 7 8 22 8 22 14 5 14 FR HEL H45K M8 7 8 38 8 38 22 5 22 FR H...

Page 23: ...ructure Transport and Tourism of Japan For a motor of less than 0 4kW the power factor improving effect will be slightly lower Power factor improving effect 1 Power supply power factor approx 93 94 4...

Page 24: ...e Model Motor Capacity W W1 H D 2 D2 Mass kg FR HEL 0 4K 0 4K 70 60 71 61 21 0 4 FR HEL 0 75K 0 75K 85 74 81 61 21 0 5 FR HEL 1 5K 1 5K 85 74 81 70 30 0 8 FR HEL 2 2K 2 2K 85 74 81 70 30 0 9 Model Mot...

Page 25: ...15 5 6 FR HEL 30K 30K 114 72 100 200 125 101 135 7 8 FR HEL 37K 37K 133 86 117 195 115 98 135 10 FR HEL 45K 45K 133 86 117 205 125 108 140 11 FR HEL 55K 55K 153 126 132 209 135 122 140 12 5 Model Moto...

Page 26: ...ion hole for 2 M5 varnish removed Max78 90 2 5 75 Max 60 28 Terminal layout P P1 Terminal Screw Size Mass kg M3 5 0 6 D3 H 2 5 Max D Installation hole for 4 M4 varnish removed D2 W 2 5 50 D1 1 Termina...

Page 27: ...HEL H5 5K 5 5K 96 60 128 100 95 75 48 M5 3 FR HEL H7 5K 7 5K 96 60 128 105 100 80 50 M5 3 5 D3 H 2 5 Max D Installation hole for 4 d varnish removed D2 W 2 5 W1 D1 1 Terminal layout P P1 Model Motor C...

Page 28: ...s kg FR HEL H75K 75K 140 120 320 295 185 16 FR HEL H90K 90K 150 130 340 310 190 20 Unit mm E P1 P P1 P W1 MAX D for S screw 4 mounting hole for M6 screw Earth ground terminal for M12 bolt 2 terminal H...

Page 29: ...Motor Capacity W W1 H H1 D S S1 S2 Mass kg FR HEL H220K 220K 175 150 405 370 240 M8 M6 M6 M12 30 FR HEL H250K 250K 190 165 440 400 250 M8 M8 M8 M12 35 FR HEL H280K 280K 190 165 440 400 255 M8 M8 M8 M1...

Page 30: ...H160K 355K Print Date Manual Number Revision Mar 2004 IB NA 0600183 A First edition Nov 2004 IB NA 0600183 B FR HEL 0 4K to 55k Cable Size and Crimping Terminal Aug 2011 IB NA 0600183 C Earthing Groun...

Page 31: ...14 MEMO...

Page 32: ...877 2 054 287 8866 054 287 8484 920 0811 255 076 252 9519 076 252 5458 SC 531 0076 1 4 13 06 6458 9728 06 6458 6911 612 8444 8 075 611 6211 075 611 6330 670 0836 6 76 079 281 1141 079 224 3419 SC 732...

Page 33: ...NAM COMPANY LIMITED Unit 01 04 10th Floor Vincom Center 72 Le Thanh Ton Street District 1 Ho Chi Minh City Vietnam TEL 84 8 3910 5945 FAX 84 8 3910 5947 FA MITSUBISHI ELECTRIC INDIA PVT LTD Pune Branc...

Page 34: ...7 220 8118 2 2 1 18 045 224 2623 920 0031 3 1 1 076 233 5502 451 8522 6 1 052 565 3323 471 0034 1 5 10 0565 34 4112 530 8206 2 2 2 06 6347 2831 730 8657 7 32 082 248 5345 760 8654 1 1 8 087 825 0055 8...