10
MAINTENANCE
1
DISPLAYING THE POWER LOSS LIST (POWER LOSS LIST)
Turn the JOG dial to select “POWER LOSS LIST”. Turn the SHUTTLE ring to the right to display the
Power Loss List. Power failure start times are stored in memory, so it is possible to confirm when they
have occurred. Up to 3 power failure start times will be displayed. If more than 3 failures have occurred,
the first and last 2 power failure start times will be displayed.
2
DISPLAYING THE ALARM LIST (ALARM LIST)
Turn the JOG dial to select “ALARM LIST”. Turn the SHUTTLE ring to the right to display the Alarm List. Alarm record start times
are stored in memory, so it is possible to confirm when they have occurred. Up to 3 alarm record start times will be displayed. If
more than 3 alarm records have occurred, the first and the last 2 alarm record start times will be displayed.
3
INITIALIZING ALL MENU SETTINGS (ALL MENU INITIALIZE)
Turn the SHUTTLE ring to the right and “ALL MENU INITIALIZE” will be displayed. When the SHUTTLE ring is turned to the left,
each setting is initialised except the TIMER RECORDING setting. When the SHUTTLE ring is turned to the right, the “MAINTENANCE”
menu will be displayed.
4
CLEARING THE POWER LOSS LIST (POWER LOSS LIST CLEAR)
Turn the SHUTTLE ring to the right and “POWER LOSS LIST CLEAR” will be displayed. When the SHUTTLE ring is turned to the
left, the Power Loss List is cleared. When the SHUTTLE ring is turned to the right, the “MAINTENANCE” menu will be displayed.
5
CLEARING THE ALARM LIST (ALARM LIST CLEAR)
Turn the SHUTTLE ring to the right and “ALARM LIST CLEAR” will be displayed. When the SHUTTLE ring is turned to the left, the
alarm list is cleared. When the SHUTTLE ring is turned to the right, the “MAINTENANCE” menu will be displayed.
FIRST TIME SET UP
1
SETTING THE OPERATION WHEN THE TAPE REACHES THE END (TAPE END)
Sets the state of operation of the VCR when the tape runs out during recording.
STOP:
The tape stops. “End” will appear on the fluorescent display and “Tape End” will appear on
the monitor. When “CALL OUT” is set to “WRNG•TAPE END”, a CALL signal is output from
the CALL terminal.
REWIND: Rewinds the tape to the beginning and stops (except during timer recording).
When “CALL OUT” is set to “WRNG•TAPE END”, a CALL signal is output for 2 seconds from the CALL terminal.
REPEAT: Rewinds the tape to the beginning and resumes recording.
ALARM•PROT(ALARM PROTECTION):
If alarm recordings are present on the tape, then the tape stops. “End” will appear on the fluorescent display and “Tape
End” will appear on the monitor. When “CALL OUT” is set to “WRNG•TAPE END”, a CALL signal is output from the CALL
terminal. If there are no alarm recordings, the tape is rewound and recording continues.
2
SETTING QUASI-V-SYNC (QUASI V-SYNC)
Sets Quasi-V-Sync on or off.
ON:
Quasi-V-Sync signal is inserted on the video output signal when in the special playback modes (still, slow motion, reverse,
fast playback, speed search) and during normal playback in L18H, L24H, 24H - 168H or 0H mode.
OFF: Quasi-V-Sync signal is not inserted.
N
Some multiplexers may require the Quasi-V-sync OFF in order to work properly.
3
SETTING THE TAPE LENGTH (TAPE LENGTH)
For the tape indicator to operate correctly the tape length must be set according to the tape being used.
E-180: When using E-180 tape
E-240: When using E-240 tape
4
SETTING THE HEADS FOR PLAYBACK (PB HEAD SELECT)
Sets the heads for playback. When the JOG dial is turned to the right, the display will be switched in the order of NORMAL
}
L/L(LEFT/LEFT)
}
R/R (RIGHT/RIGHT)
}
AUTO
}
NORMAL
}
...
•
This VCR is equipped with two pairs of SP heads. Some VCRs make Time Lapse recordings using same Azimuth heads which
are not VHS compatible. Playback of such tapes with the Normal setting will have picture/noise with a 30 HZ flicker, or just noise.
To obtain proper playback, adjust the setting to AUTO, or set to L/L or R/R. One setting will provide normal play. After playing a
tape with L/L or R/R settings, return the setting to NORMAL.
5
SETTING THE BUZZER ON/OFF (BUZZER)
Sets the state in which the buzzer sounds.
WRNG
: The buzzer sounds when there is any malfunction in the VCR.
WRNG•REMAIN
: The buzzer sounds when there is any malfunction in the VCR or when the tape (E-180 or E-240) has
approximately 3 minutes left in 3H mode.
WRNG•TAPE END
: The buzzer sounds when there is any malfunction in the VCR or at the tape end.
OFF
: The buzzer does not sound.
6
SETTING THE PRESENT TIME, DATE AND DAYLIGHT SAVING TIME SETTINGS (TIME DATE ADJUST)
Refer to the pages 11 - 12.
0
0H
<MAINTENANCE>
POWER LOSS LIST
ALARM LIST
ALL MENU INITIALIZE
POWER LOSS LIST CLEAR
ALARM LIST CLEAR
<
REPEAT REC TIMES
>
<
ELAPSED TIME
>
<
FIRST TIME SET UP
>
TAPE END
QUASI V-SYNC
TAPE LENGTH
PB HEAD SELECT
BUZZER
TIME DATE ADJUST
STOP
ON
E-180
NORMAL
WRNG
Summary of Contents for HS-7168E
Page 32: ...872C191D3 PRINTED IN JAPAN ...