15
MANUAL RECORDING
Recording time
mode
REPEAT RECORDING
When the “TAPE END” of the “FIRST TIME SET UP” menu is set to “REPEAT” or “ALARM•PROT” and the repeat recording mode is set
(the REPEAT indicator is illuminated), the tape will automatically be rewound to the start when the tape end is reached. Then recording
will start again.
2
WHEN TAPE END IS REACHED
The following functions are automatically engaged when the tape ends during recording :
STOP
REWIND
REPEAT
ALARM•PROT
The tape is rewound
automatically to the
beginning and recording
is resumed.
The tape is rewound
automatically to the
beginning and then
stops.
The tape stops.
When there are alarm
recordings on tape.
The tape stops.
The tape is rewound
automatically to the
beginning and then the
rcroding is resumed.
When there are no
alarm recordings on
tape.
RECOMMENDED NUMBER OF TAPE USE
Video tape becomes worn during use. A new cassette should be utilised according to the following chart.
Number of tape use
E-180 cassette
E-240 cassette
100
60
35
20
50
30
17
–
3H, 6H
L18H
L24H
48H
N
•
On “ALARM•PROT” mode, a tape with alarm recordings can be used for repeat recording if the tape is ejected and re-inserted.
THE NUMBER OF TAPE USE (REPEAT REC TIMES)
Displays the number of tape use when the TAPE END setting is set to “REWIND”, “REPEAT” or
“ALARM•PROT”.
1. Press the DISPLAY button. MAIN MENU display will appear.
2. Turn the jog dial to select “MAINTENANCE” and turn the SHUTTLE ring to the right to enter.
“MAINTENANCE” will appear on the display. “REPEAT REC TIMES” indicates the number of times
a tape has been repeatedly recorded on.
•
The number of tape use counts up by one when the tape ends.
•
The number of tape use is memorised even if the mains supply is removed, provided the backup is active.
•
The number of tape use is reset when the current tape is replaced with another.
3. Press the DISPLAY button. The present time will be displayed.
Recording time
mode
Number of tape use
E-180 cassette
E-240 cassette
SET
RST
IN
REC
GND ALM MODE
CLK CALL
OUT
SET
RST
IN
REC
GND ALM MODE
CLK CALL
OUT
SERIES RECORDING
[*1]
Series recording is possible if two or more of these units are connected together. When the tape in the first VCR reaches the end during
recording, the tape in the second VCR automatically begins recording.
1. Set the “REC IN” of “REAR TERMINAL” menu to “SERIES”.
2. Set the “CALL OUT” of “REAR TERMINAL” menu to “WRNG•TAPE END”.
3. Set the “TAPE END” of “FIRST TIME SET UP” menu to “REWIND”.
N
• Series recording may have a short pause (
≈
5 seconds) when going from recorder A to recorder B. However, if you set the CALL OUT
of the “REAR TERMINAL” menu to “WRNG•REMAIN”, this delay is eliminated.
• When set in the above configuration and the second VCR reaches the end of the tape, the first VCR automatically begins recording.
Do not connect [*1], if you do not require the first VCR to begin recording again.
• If an abnormality occurs (eg., a malfunction occurs in the motor during recording) in the first VCR, the second VCR automatically
begins recording.
• Series recording will not function during timer recording.
• When carrying out series recording, set “CALL OUT” in the “REAR TERMINAL” menu to a mode other than “WRNG”.
0
0H
<
REPEAT REC TIMES>
<
ELAPSED TIME>
15
10
8
–
–
–
72H, 96H
120H
168H
Summary of Contents for HS-7168E
Page 32: ...872C191D3 PRINTED IN JAPAN ...