26
Installation
Note
A point to notice
Info.
Supplementary information
Connections for Various Functions
Alarm Recording Connection
The alarm can be confirmed from a distance by connecting the
ALM OUT terminal with an existing alarm system panel or other
peripherals such as a buzzer. Connect the VCR and other
peripherals as to the right. (
page 11 for the menu setting
and page 37 for the rating of each terminal)
Alarm set switch
Alarm reset switch
External alarm lamp
and buzzer
RST
IN
REC GND ALM
ALM
MODE
CLK
OUT
CALL
AUDIO
VIDEO
OUT
OUT
IN
REMOTE
IN
S-VIDEO
OUT
IN
RESET
RST
IN
REC GND ALM
ALM
MODE
CLK
OUT
CALL
MIC
VIDEO
OUT
AUDIO
OUT
VIDEO IN
AUDIO IN
SENSOR
CCTV CAMERA
ALM IN
GND
VIDEO
IN
S-VIDEO
IN
VIDEO OUT
S-VIDEO
OUT
MONITOR
MIC
IN
MICROPHONE
S-VIDEO OUT
S-VIDEO IN
One of either codes
should be connected.
One of either codes
should be connected.
Connecting with CCTV camera, monitor and sensor
Note
•
Monitor to be connected
–
Connecting with a CCTV monitor (for surveillance) is recommended.
–
Connecting with some monitors may cause picture vibration and/or picture distortion at the top or bottom of the image at still
picture or normal playback.
–
A television for domestic use may easily cause the picture vibration and distortion.
•
CCTV camera to be connected
–
Do not connect ‘Color’ and ‘Black & White’ cameras together.
•
When both S-VIDEO IN terminal and VIDEO IN terminal are connected with the CCTV camera, the signal through S-VIDEO IN
terminal is given priority.