background image

 

- 26 - 

 

 

name

 

Function

 

No.

 

 

IA. 

IA input function selection

 

0300 

 

IAL. 

IA input logic changeover

 

0301 

 

IAA. 

IA input alternating operation

 

0302 

 

IB. 

IB input function selection

 

0303 

 

IBL. 

IB input logic changeover

 

0304 

 

IBA. 

IB input alternating operation

 

0305 

 

IC. 

IC input function selection

 

0306 

 

ICL. 

IC input logic changeover

 

0307 

 

ICA. 

IC input alternating operation

 

0308 

 

ID. 

ID input function selection

 

0309 

 

IDL. 

ID input logic changeover

 

0310 

 

IDA. 

ID input alternating operation

 

0311 

 

IE. 

IE input function selection

 

0312 

 

IEL. 

IE input logic changeover

 

0313 

 

IEA. 

IE input alternating operation

 

0314 

 

IF. 

IF input function selection

 

0315 

 

IFL. 

IF input logic changeover

 

0316 

 

IFM. 

Setting the function for IF

 

0317 

 

RFS. 

Set condition of RS F/F for IF

 

0318 

 

RFR. 

Reset condition of RS F/F for IF

 

0319 

 

RFN. 

RS F/F reset stitch amount for IF

 

0320 

 

IG. 

IG input function selection

 

0321 

 

IGL. 

IG input logic changeover

 

0322 

 

IGA. 

IG input alternating operation

 

0323 

 

IH. 

IH input function selection

 

0324 

 

IHL. 

IH input logic changeover

 

0325 

 

IHA. 

IH input alternating operation

 

0326 

 

II. 

II input function selection

 

0327 

 

IIL. 

II input logic changeover

 

0328 

 

IIA. 

II input alternating operation

 

0329 

 

IJ. 

Not used.

 

0330 

 

IJL. 

Not used.

 

0331 

 

IJA. 

Not used.

 

0332 

 

IK. 

Not used.

 

0333 

 

IKL. 

Not used.

 

0334 

 

IKA. 

Not used.

 

0335 

 

IL. 

Not used.

 

0336 

 

ILL. 

Not used.

 

0337 

 

ILA. 

Not used.

 

0338 

 

IM. 

IM input function selection

 

0339 

 

IML. 

IM input logic changeover

 

0340 

 

IMA. 

IM input alternating operation

 

0341 

 

IN. 

IN input function selection

 

0342 

 

INL. 

IN input logic changeover

 

0343 

 

INA. 

IN input alternating operation

 

0344 

 

IO. 

IO input function selection

 

0345 

 

IOL. 

IO input logic changeover

 

0346 

 

IOA. 

IO input alternating operation

 

0347 

 

IP. 

IP input function selection

 

0348 

 

IPL. 

IP input logic changeover

 

0349 

 

IPA. 

IP input alternating operation

 

0350 

 

IQ. 

IQ input function selection

 

0351 

 

IQL. 

IQ input logic changeover

 

0352 

 

IQA. 

IQ input alternating operation

 

0353 

 

IR. 

IR input function selection

 

0354 

 

IRL. 

IR input logic changeover

 

0355 

 

IRA. 

IR input alternating operation

 

0356 

 

I1. 

I1 input function selection

 

0357 

 

I1L. 

I1 input logic changeover

 

0358 

 

I1M. 

Setting the function for I1

 

0359 

 

I1O 

Special setting for input signal "I1" 

0360 

 

I1F 

Special setting for input signal "I1" is ON 

0361 

 

I1C 

RS F/F clear setting 

0362 

 

1CT 

RS F/F delay time setting 

0363 

 

F1P 

Input signal I1 virtual F/F circuit operation 1 

0364 

 

F1C 

Input signal I1 virtual F/F circuit operation 2 

0365 

 

F1S 

Input signal I1 virtual F/F circuit operation 3 

0366 

 

R1S 

Set condition of RS F/F for I1

 

0367 

 

R1R 

Reset condition of RS F/F for I1

 

0368 

 

R1N 

RS F/F reset stitch amount for I1

 

0369 

 

I2. 

I2 input function selection

 

0370 

 

I2L. 

I2 input logic changeover

 

0371 

 

I2M. 

Setting the function for I2

 

0372 

 

I2C 

RS F/F clear setting 

0373 

 

2CT 

RS F/F delay time setting 

0374 

 

R2S 

Set condition of RS F/F for I2

 

0375 

 

R2R 

Reset condition of RS F/F for I2

 

0376 

 

R2N 

RS F/F reset stitch amount for I2

 

0377 

    

 

 

name

 

Function

 

No.

 

 

I4. 

I4 input function selection

 

0378 

 

I4L. 

I4 input logic changeover

 

0379 

 

I4A. 

I4 input alternating operation

 

0380 

 

I5. 

I5 input function selection

 

0381 

 

I5L. 

I5 input logic changeover

 

0382 

 

I5A. 

I5 input alternating operation

 

0383 

 

I6. 

I6 input function selection

 

0384 

 

I6L. 

I6 input logic changeover

 

0385 

 

I6A. 

I6 input alternating operation

 

0386 

 

I7. 

I7 input function selection

 

0387 

 

I7L. 

I7 input logic changeover

 

0388 

 

I7A. 

I7 input alternating operation

 

0389 

 

OA. 

OA output function selection

 

0390 

 

OAL. 

OA output logic changeover

 

0391 

 

OAC. 

OA output chopping operation

 

0392 

 

OAT. 

OA output forced OFF

 

0393 

 

DA. 

OA output delay time

 

0394 

 

OB. 

OB output function selection

 

0395 

 

OBL. 

OB output logic changeover

 

0396 

 

OBC. 

OB output chopping operation

 

0397 

 

OBT. 

OB output forced OFF

 

0398 

 

DB. 

OB output delay time

 

0399 

 

OC. 

OC output function selection

 

0400 

 

OCL. 

OC output logic changeover

 

0401 

 

OCC. 

OC output chopping operation

 

0402 

 

OCT. 

OC output forced OFF

 

0403 

 

DC. 

OC output delay time

 

0404 

 

OD. 

OD output function selection

 

0405 

 

ODL. 

OD output logic changeover

 

0406 

 

ODC. 

OD output chopping operation

 

0407 

 

ODT. 

OD output forced OFF

 

0408 

 

DD. 

OD output delay time

 

0409 

 

OF. 

OF output function selection

 

0410 

 

OFL. 

OF output logic changeover

 

0411 

 

FUD. 

Presser foot lifter output chopping duty

 

0412 

 

FO. 

Presser foot lifter FU full wave output time

 

0413 

 

FU. 

Presser foot lifter FU momentary mode

 

0414 

 

DF. 

OF output delay time

 

0415 

 

O1. 

O1 output function selection

 

0416 

 

O1L. 

O1 output logic changeover

 

0417 

 

O1C. 

O1 output chopping function

 

0418 

 

O1T. 

O1 output forced OFF

 

0419 

 

D1. 

O1 output delay time

 

0420 

 

O2. 

O2 output function selection

 

0421 

 

O2L. 

O2 output logic changeover

 

0422 

 

O2C. 

O2 output chopping function

 

0423 

 

O2T. 

O2 output forced OFF

 

0424 

 

D2. 

O2 output delay time

 

0425 

 

O3. 

O3 output function selection

 

0426 

 

O3L. 

O3 output logic changeover

 

0427 

 

O3C. 

O3 output chopping function

 

0428 

 

O3T. 

O3 output forced OFF

 

0429 

 

D3. 

O3 output delay time

 

0430 

 

O4. 

O4 output function selection

 

0431 

 

O4L. 

O4 output logic changeover

 

0432 

 

O4T. 

O4 output forced OFF

 

0433 

 

D4. 

O4 output delay time

 

0434 

 

O5. 

O5 output function selection

 

0435 

 

O5L. 

O5 output logic changeover

 

0436 

 

O5T. 

O5 output forced OFF

 

0437 

 

D5. 

O5 output delay time

 

0438 

 

O6. 

O6 output function selection

 

0439 

 

O6L. 

O6 output logic changeover

 

0440 

 

O6C. 

O6 output chopping function

 

0441 

 

O6T. 

O6 output forced OFF

 

0442 

 

D6. 

O6 output delay time

 

0443 

 

O7. 

O7 output function selection

 

0444 

 

O7L. 

O7 output logic changeover

 

0445 

 

O7C. 

O7 output chopping function

 

0446 

 

O7T. 

O7 output forced OFF

 

0447 

 

D7. 

O7 output delay time

 

0448 

 

OM. 

OM output function selection

 

0449 

 

OML. 

OM output logic changeover

 

0450 

 

OMT. 

OM output forced OFF

 

0451 

 

DM. 

OM output delay time

 

0452 

 

ON. 

ON output function selection

 

0453 

 

ONL. 

ON output logic changeover

 

0454 

 

ONT. 

ON output forced OFF

 

0455 

 

C

 m

od

e

 (

Fo

se

tt

ing

 i

np

u

t/

ou

tpu

si

gn

al

 t

o

 f

un

ct

ion

):

 [

↓]

+

[C

key

 

C

 m

od

e

 (

Fo

se

tt

ing

 i

np

u

t/

ou

tpu

si

g

na

to

 f

un

ct

ion

):

 [

↓]

+

[C

key

 

Summary of Contents for Limiservo X G Series

Page 1: ...duction type AC servo motor and control box with automatic needle positioner Thank you for purchasing this product Please read this manual thoroughly before use to ensure safe and proper use Please re...

Page 2: ...the solenoid voltage and output voltage 12 1 To change solenoid voltage DC24V DC30V 12 2 Changing the output voltage between 0VDC and 5VDC 12 10 Operation of the Control switch Panel Keys 13 1 Display...

Page 3: ...eets the specifications on the motor and control box rating nameplates before connecting it to the power line Connect it to the designated places to supply the power Perform this step with the power s...

Page 4: ...The same operation should be taken when the position detector or wires are broken 13 Be sure to ground the lever unit when using it to separate from the control box 14 Always turn off the power switc...

Page 5: ...achine connector Motor connector Lever Lever Unit Power connector Status indication LED Connector indication nameplate High voltage warning plate XC G10 S control switch panel installation screw hole...

Page 6: ...djust the belt tension press down on the center of the belt with your hand and turn the upper and lower nuts of the adjustment nut to increase or decrease the center height of the motor so that the be...

Page 7: ...direction and install between the belt and motor pulley a For counterclockwise rotation b For clockwise rotation Set the center of the protective rod to the position at the center of the belt and mot...

Page 8: ...Wire the units as shown below Align the connector shape and direction and securely insert it View of control box from cover side View of control box from box side This can not be used with except XC...

Page 9: ...h insulation tape etc to insulate securely Always ground the green yellow green grounding wire 6 Wire and Grounding Power connector 6 Pole Power connector Power Recommended current capacity Single pha...

Page 10: ...the sewing machine be rotated lightly by hand 2 Turn on the power 1 Does the status indication LED on the control box light up in green There is a problem if the LED is flickering or is lit up in red...

Page 11: ...esignated stop position The cross recessed screw A does not need to be loosened at this time Always replace the cover after adjustment 2 Adjustment of pedal toe down pressure and heeling pressure The...

Page 12: ...Slow start speed S 250 Operation speed Adjust between the low speed L and high speed H using the C and D keys on the control switch panel Caution No matter how large the motor pulley diameter is the...

Page 13: ...ight Change the output voltage 0 5VDC with the jumper JP5 on the front cover PCB 3 The output voltage can be changed by reconnecting the connector as shown on the right 4 The factory setting Connector...

Page 14: ...can be investigated Program mode I Save mode of the setting data Program mode R Reset returning to original data The state set with each program mode can be returned to the original settings factory...

Page 15: ...ay will flicker Press down key press key The program mode C will be entered Switch the function item with the or key Program mode D While holding down the key press the D key for 2 seconds or more fro...

Page 16: ...er of Function item number selection mode normal mode Press after changing the setting for each function item The display LED will flicker and after the changed items are set the mode will change to t...

Page 17: ...se when the pedal is pressed down to the fullest The speed ratio is displayed with the two digits LED C and LED D and can be set in the range of 0 to 99 Slow start ON OFF Slow start can be turned ON o...

Page 18: ...tor and the No of stitches can be set 1 When the except pattern No 4 2 When the pattern No 4 continuous tack stitching Each setting value can be changed from 0 to 9 stitches A B C D E F stitches A mea...

Page 19: ...pattern 2 or 3 display show 2 or 3 2 Display of continuous tack stitching Pattern 4 3 Display of program stitching Pattern A to H Display of pattern A When pattern B C D E F G or H display show B C D...

Page 20: ...y setting is 280M B After selecting the function name holds down the D key over 2 seconds or more The function name s set speed and function setting will be set automatically To return to the normal m...

Page 21: ...700 700 ON OFF H 65 6850 LY3 6850 B1T 2000 250 150 700 700 ON OFF L 410B LU2 4410 B1T 2000 250 175 700 700 ON OFF L 8 412B LU2 4412 B1T 2000 250 175 700 700 ON OFF L 430B LU2 4430 B1T 2000 250 175 700...

Page 22: ...gs Description A Select the function that corresponds to the sewing machine model for Simple setting table for chain stitch sewing machine on the page 22 After selecting the function name holds down t...

Page 23: ...tch Electric under thread trimmer 1 6000 200 200 1400 1400 NO7A PEGASUS W T 600 200 series UT device condensed stitch Pneumatic under thread trimmer with pneumatic top cover thread trimmer 1 6000 200...

Page 24: ...econds or more This completes the settings Description A Select the model name that corresponds to the sewing machine model for the simple setting values for the D RKOPP ADLER thread trimming sewing m...

Page 25: ...B 6 OB DLU 5490BB 6 WB DLU 5490N 6 DMN 530 5 DMN 531 5 class 2 4200 200 200 1700 1900 JDU JUKI DNU 241H 5 DNU 241H 6 DSC 244 6 DSC 244V 6 DSC 245 5 DSC 245 6 DSC 246 6 DSC 246V 6 DSU 142 6 DSU 144 6 D...

Page 26: ...sed 0053 D8 Needle DOWN position stop angle 0054 U8 Needle UP position stop angle 0055 name Function No GA Gain high low selection 0100 PDC Pedal curve 0101 AC Acceleration time simple setting 0102 AC...

Page 27: ...0375 R2R Reset condition of RS F F for I2 0376 R2N RS F F reset stitch amount for I2 0377 name Function No I4 I4 input function selection 0378 I4L I4 input logic changeover 0379 I4A I4 input alternati...

Page 28: ...or virtual output OT2 0511 T3C Virtual output OT3 forced OFF function 0512 T3T Forced OFF timer setting function for virtual output OT3 0513 D11 ON delay time setting function for virtual output OT1 0...

Page 29: ...he voltage of VC2 0736 OAD Output signal display 0737 OBD Output signal display 0738 OCD Output signal display 0739 ODD Output signal display 0740 OFD Output signal display 0741 O1D Output signal disp...

Page 30: ...g 2 O1 OT1 Output 3 VC2 VC2 Variable speed command 4 I5 No setting 5 I1 IO1 Input 6 5V 12V 5V 7 24V 30V 24V 8 I2 U Needle lift signal 9 0V 0V 10 24V 30V 24V 11 O2 NCL Needle cooler output 12 O7 No set...

Page 31: ...r after turning OFF the power switch 2 Turn ON the power switch and then set the function PDS to ON The lever connector still disconnects 3 Connect the lever connect after turning OFF the power switch...

Page 32: ...play LED on the control box flickers in orange colored as the interval of 0 3 sec It will be confirmed in error code history after returning to a normal condition M5 An error of the copy mode using th...

Page 33: ...rating 10 or more continuous time rating OA Thread trimming output T 4 or more short time rating 5 or more short time rating OB Wiper output W 4 or more short time rating 5 or more short time rating O...

Page 34: ...Reference Dimensions MOTOR and CONTROL BOX Printed in Japan...

Reviews: