EN – 26
Indicators
The projector has three LED Indicators which shows the working condition of the projector.
The following offers solutions to possible problems. If a problem persists, turn the projector off and consult your
dealer.
Normal condition
Abnormal condition
Steady
red
Steady
green
Steady
green
Blinking
green
Steady
green
POWER LAMP
TEMP
CONDITION
Notes
The POWER is ON. (Normal condition)
Lamp stand-by (about for 1 minute)
The power button cannot be used to switch
ON and OFF
Stand-by
Off
Off
Off
Off
Steady
green
Blinking
green/red
Blinking
green/red
Blinking
green/red
Steady
red
Steady
green
Steady
green
Blinking
red
Blinking
red
POWER LAMP
TEMP
CONDITION
POSSIBLE SOLUTIONS
Lamp duration warning. (Lightning duration total
about 1, 500 hours.When the POWER is ON.)
Steady
red
Blinking
red
Lamp duration warning. (Lightning duration total
about 1, 500 hours.When the POWER is OFF.)
Steady
red
Lamp duration warning. (Lightning duration total
about 2,000 hours.)
The lamp or filter cover is not closed.
Close the cover correctly.
or
or
Blinking
Blinking
Abnormal.
Contact your dealer.
Off
Off
Off
Off
Off
Off
Steady
red
Steady
Steady
Unusual temperature
• The ventilation slits or air filter is clogged with
dust or debris.
• The fan has stopped due to an impediment.
• The room temperature is too high.
• The filter is dirty.
• Remove the object from the ventilation
slits.
• Pull out the power plug andremove the
object. If you cannot, consult your dealer.
• Relocate the projector to a cooler place.
• Clean the filter.
Replace the lamp.
Exchange with a new lamp if the same
problem recurs.
LAMP indicator
POWER indicator
TEMP indicator
POWER
LAMP
VOLUME
TEMP
VIDEO
ENTER
MUTE
MENU
SOURCE
COMPUTER
AUTO POSITION