(b) Ew Error Clear Area
The Ew Error Clear Area will be explained.
Error Clear
Item
Description
Ew.n+1 , Ew.n Error Clear Request
(1) Turn Ew.n ON (1) when clearing error information.
(2) After confirming that the error information has been
cleared, turn OFF (0) the Ew.n Error Clear Request.
When the module recovers from the error, the error
information is automatically cleared.
OFF (0) : Error clear not requested (default)
ON (1) : Error clear requested
Only Ew.n is used.
Ew.n+1 is reserved for the system. (0 fixed)
(c) Ww Word Output Area
The Word Output Area is not occupied.