6Appendix
Configuration flag
Appendix-101
6 Appendix
Appendix 1 : Configuration flag
The configuration flag indicates the robot posture.
For the 6-axis type robot, the robot hand end is saved with the position data configured of X, Y, Z, A, B and C.
However, even with the same position data, there are several postures that the robot can change to. The posture
is expressed by this configuration flag, and the posture is saved with FL1 in the position constant (X, Y, Z, A, B, C)
(FL1, FL2).
The types of configuration flags are shown below.
(1) RIGHT/LEFT
Indicates the location of the end axis relative to the line that passes through both the rotational center of the J1
axis and the rotational center of the J2 axis.
Fig.6-1 : Configuration flag (RIGHT/LEFT)
J2軸
Extension line of the
No.1 arm
RIGHT
LEFT
FL1(Flag 1)
& B 0 0 0 0 0 0 0 0
↑
1/0 = RIGHT/LEFT
Note) "&B" is shows the binary
J2 axis