4 - 14
4. OPERATION AND FUNCTIONS
(4) About data setting type count type 2) (QD75M) Common to all full closed encoders
In the data setting type/count type 2) (QD75M) home position return method, a home position return
can be normally made if the home position has been passed through (in either direction) before start of
a home position return, since a scale home position (reference mark) or the Z-phase signal of a rotary
encoder is not required.
When the linear scale used does not have a scale home position (reference mark) or the machine has
no distance of one motor encoder revolution until the Z phase of the rotary encoder is passed through,
a home position return can be made by changing the parameter (Pr. 33 "home position setting
condition selection") setting if the home position is not yet passed through.
Summary of Contents for Melservo-J2-SUPER series
Page 19: ...1 6 1 FUNCTIONS AND CONFIGURATION MEMO...
Page 49: ...2 30 2 LINEAR SCALES MEMO...
Page 85: ...5 8 5 PARAMETERS MEMO...