5 - 4
5. PARAMETERS
Class No. Abbreviation
Name
Initial Value
Unit
Setting
Range
23
OP1 Optional function 1:
Select the optional function 1.
0000
0000h
to
0201h
Adjus
tm
ent pa
ra
m
ete
r
The parameter marked is valid only at power-on.
Servo forced stop selection
Select the servo forced stop function of the CN3-20 input.
0: Valid (forced stop signal is used)
1: Invalid (forced stop signal is not used)monitor ch1.
Serial encoder cable selection
Select the communication systems of CH1 (for motor) and CH2 (for full
closed encoder).
When full closed function
is invalid
(Pr. 62: 0)
When full closed function
is valid
(Pr. 62: 1 or 2)
Hundreds
digit setting
ENC CH1
ENC CH2
ENC CH1
ENC CH2
0
2 wire type Unusable
2 wire type 2 wire type
1
4 wire type Unusable
4 wire type
Unusable
2
2 wire type Unusable
2 wire type 4 wire type
Summary of Contents for Melservo-J2-SUPER series