5 - 6
5. PARAMETERS
Class No. Abbreviation
Name
Initial Value
Unit
Setting
Range
Ex
pansion p
ar
amet
er
s
40
BLK Parameter write inhibit:
Select the reference and write ranges of the parameters.
0000
0000h
to
100Eh
60
OPC Optional function C:
Select the encoder pulse output direction.
0000
0000h
to
0100h
Ex
pan
sion
par
am
eter
s
2
62
FCT Full closed selection:
Select the full closed encoder rotation direction, full
closed control error detection function 1 and full closed
control error detection function 2.
1300
0000h
to
1312h
The parameters marked are valid only at power-on.
MR Configurator
Setting
Reference Range
Write Range
Other than the
following
00 to 11, 40
00 to 11, 40
000A
40
40
000C
00 to 40
00 to 11, 40
000E
00 to 40
00 to 40
000F
00 to 75
00 to 75
100E
00 to 40
40 only
Encoder pulse output direction selection
0: A-phase 90 lead for CCW
1: A-phase 90 lead for CW
Full closed function
0: Invalid
1: Always valid
2: Switching valid (semi/full switching by host controller)
Full closed encoder polarity
0: Address increasing direction for motor CCW
1: Address increasing direction for motor CW
Full closed control error detection function
Setting
Full closed control error detection function
0
Invalid
1
Full closed control error detection function 1 valid
2
Full closed control error detection function 2 valid
3
Full closed control error detection functions 1 and 2
both valid
Full closed encoder error (AL-2A) selection
0: Invalid (when ALM signal is not connected in MR-J2S-CLP01)
1: Valid