4. STARTUP
4 - 33
(2) Operation example
(a) Parameters of 5 or less digits
The following example shows the operation procedure performed after power-on to change the
control mode to the speed control mode with [Pr. PA01 Operation mode]. Press "MODE" to switch to
the basic setting parameter screen.
The parameter number is displayed.
Press "UP" or "DOWN" to change the number.
The set value of the specified parameter number flickers.
Press "SET" twice.
Press "SET" to enter.
Press "UP" twice.
During flickering, the set value can be changed.
Use "UP" or "DOWN".
(_ _ _ 2: Speed control mode)
……
……
……
To shift to the next parameter, press the "UP" or "DOWN" button.
When changing the [Pr. PA01] setting, change its set value, then switch power off once and switch it
on again to enable the new value.
(b) Parameters of 6 or more digits
The following example gives the operation procedure to change the electronic gear numerator to
"123456" with [Pr. PA06 Electronic gear numerator].
The screen flickers.
Press "MODE" to switch to the basic setting parameter screen.
Press "UP" or "DOWN" to select [Pr. PA06].
Press "SET" once.
Press "SET" once.
Setting of upper 1 digit
Press "UP" or "DOWN" to
change the setting.
Press "SET" once.
Enter the setting.
Press "MODE" once.
Press "MODE" once.
Setting of lower 4 digits
……
……
……
…
Summary of Contents for MR-J4-100A
Page 9: ...A 8 MEMO ...
Page 61: ...1 FUNCTIONS AND CONFIGURATION 1 44 MEMO ...
Page 67: ...2 INSTALLATION 2 6 MEMO ...
Page 137: ...3 SIGNALS AND WIRING 3 70 MEMO ...
Page 261: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 291: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 30 MEMO ...
Page 299: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 319: ...9 OUTLINE DRAWINGS 9 20 MEMO ...
Page 461: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 36 MEMO ...
Page 511: ...14 COMMUNICATION FUNCTION 14 38 MEMO ...
Page 559: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Page 583: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Page 621: ...APPENDIX App 38 ...
Page 639: ......